Mitsubishi Electric MELSENSOR VS20 Connection Manual page 34

Vision sensor, fa sensor
Hide thumbs Also See for MELSENSOR VS20:
Table of Contents

Advertisement

Connect the power and I/O breakout cable
Precautions
• When connecting the vision sensor and programmable controller, simultaneously turn on the vision sensor and
programmable controller, or first turn on the programmable controller.
• Cut unused wires or protect them with insulating materials. Keep all bare wires separated from the 24 V DC wire.
1.
Verify that the 24 V DC power supply being used is unplugged and not receiving power.
2.
Connect the wires of the power and I/O breakout cable, I/O module and power supply as shown below.
24 V DC
power supply
3.
Connect the power and I/O breakout cable's M12 connector to the vision sensor's Power, I/O and RS-232 connector.
4.
Turn on the 24 V DC power supply switch.
2 I/O CONNECTION
32
2.1 Introduction
Trigger (Orange)
General input 0 (Violet)
High-speed output 0 (Blue)
High-speed output 1 (Grey)
High-speed output 2 (Yellow)
High-speed output 3 (White/Brown)
Input common (White/Violet)
Output common (Green)
24 V DC (Red)
GND (Black)
Power and I/O