Hide thumbs Also See for MELSENSOR VS20:
Table of Contents

Advertisement

3.
Set the SLMP Scanner.
• SLMP response from the programmable controller may be delayed due to on-line operation to the
programmable controller, etc., making connections disconnected in some cases, so ensure a sufficient
margin for the timeout time.
• Shortening the poll interval also shortens the interval to monitor the programmable controller status.
Assigning devices
1 THE SLMP SCANNER CONNECTION
16
1.3 Vision Sensor Setting
 Configure the settings as shown
left.
• Controller Type: iQ-R/Q/L Series
(3E Frame)
• IP Address: 192.168.3.2
• Host Port: 12289 (Port No. of the
Ethernet parameter set in GX
Works3)
• Timeout (ms): 1000
• Poll interval (ms): 100
 Select [Device Addressing].
 Set a selected device, offset, and
the number of devices to each of the
six data blocks as shown left.
For control contents of when the
device is assigned to each data block,
refer to Page 25 Contents in data
blocks.