■Device assignment to be used status bit block
Classification
Device
Status Bit Blocks
D1002.0
D1002.1
D1002.2
D1002.3
D1002.4
D1002.5
D1002.6
D1002.7
D1002.8
D1002.9
D1002.A
D1002.B
D1002.C
D1002.D
D1002.E
D1002.F
D1003.0
D1003.1
D1003.2
D1003.3
D1003.4
D1003.5
D1003.6
D1003.7
D1003.8
D1003.9
D1003.A
D1003.B
D1003.C
D1003.D
D1003.E
D1003.F
■Device Assignment to be Used Output Word Blocks
Classification
Device
Output Word Blocks
D1010
D1011
D1012
D1013
D1014
D1015
to
D1021
Control Details (Application)
Network Trigger Ready
Trigger ON Acknowledgment
Reserved
Importing Failed
Offline Reason
Online
System Busy
Inspection Completed
Result Buffer Overrun
Results Valid
Job Loading
Job Load Complete
Job Load Failed
Fault
Set User Data Trigger Acknowledgment
Send Native Mode Command Trigger Acknowledgment
Native Mode Command Error
Imaging Completed
Job Pass
Soft Event 0 Trigger Acknowledgment
Soft Event 1 Trigger Acknowledgment
Soft Event 2 Trigger Acknowledgment
Soft Event 3 Trigger Acknowledgment
Soft Event 4 Trigger Acknowledgment
Soft Event 5 Trigger Acknowledgment
Soft Event 6 Trigger Acknowledgment
Soft Event 7 Trigger Acknowledgment
Control Details (Application)
Loaded Job ID
Error Code
Image Import ID
Inspection Result ID
Image Inspection Result Code
Inspection Result
Supplement
This bit turns on when the trigger can be input.
This bit notifies that the trigger ON is acknowledged.
This bit remains ON until the "trigger" bit is cleared.
This bit turns on when importing an image failed.
This bit is cleared when importing an image is properly
completed.
0: Online status
1: Offline operation from the program
2: Offline operation from the discrete signal input
3: Offline operation from the communication
This bit turns on when the vision sensor is online.
This bit turns on during inspection processing.
This bit changes (toggles) the status when inspection is
completed.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
It cannot be used with this model.
Supplement
These devices store the data that has been specified with
the format output data and is to be output from the vision
sensor.
In this example these are as shown below.
• D1015: Pattern_1.PASS
• D1016: Pattern_1.FAIL
• D1017: Job Inspection Count