1 THE SLMP SCANNER CONNECTION
20
1.4 Setting the Programmable Controller
 Double-click [Module Parameter] in the Navigation window.
Set [Module Parameter] of R04CPU as
shown left.
 IP Address: 192.168.3.2
 Enable/Disable Online Change:
Enable All (SLMP)
Communication Data Code: Binary
 Click [External Device
Configuration].
 Select "SLMP Connection Module"
from the module list and paste by
drag&drop.
 Select "TCP" in "Protocol".
 Input "12289" to "Port No.".
 Click [Close with Reflecting the
Setting].