Mounting Cabinets - Mitel MX-ONE Installation Instructions Manual

Installing chassis in a cabinet
Hide thumbs Also See for MX-ONE:
Table of Contents

Advertisement

I
C
NSTALLING
HASSIS IN A
2.2
2.2.1
7
C
ABINET
Figure 2:
Workflow for the MX-ONE Hardware Installation

MOUNTING CABINETS

This section describes mounting of the cabinets. The instructions focus on the BYB 501
cabinets. For installation of the standard server cabinet, see the manufacturer instruc-
tions.
After this installation phase, all cabinets are positioned, fastened, leveled, and
anchored to the site floor.
UNPACKING
When unpacking the cabinet, perform the following steps:
1.
Open the cabinet case using the Vikex opener.
2.
Lift the cabinet using a cabinet hoist or at least four people.
3.
Place the cabinet on the floor in an upright position. Take extra care to avoid the
cabinet from tipping over, as it is not yet secured to the floor.
4.
Remove the plastic wrapping from the cabinet.
5.
Move the cabinet to its position according to the floor marking, using a cabinet
lifter or at least four people.
20/1531-ASP11301 Uen B5 2017-03-23