INTERNAL SETUP and CONNECTIONS
I N P U T S
C A M 1

INTERNAL SETUP

CAUTION
components with hazardous voltages, the
performed by qualified service personnel only.

Video Input Termination

Two internal jumpers, 54 and 56, are provided to independently
set the termination of each rear panel video input.
associated jumper to the 75R position.
loop-through video output, set the jumper to HiZ.
The location of these ,jumpers on the AD1562 PCB is shown in
Figure 3. Figure -1 illustrates the position settings for either
jumper. As shipped. both jumpers are set to 75Q termination.
Transfonner
Figure 3 - Location of Termination Jumpers on PCB
setting
Figure 4 - Termination Jumper Positions
CAM2
O U T P U T
Figure 2 - AD1 562 DuoTect-C Rear Panel
75Rsetting

ALARM OUTPUTS

CONNECTIONS

All connections are on the AD1562 rear panel. see Figure 2.

Video Inputs

Two pairs of BNC connectors labeled INPUTS CAM1 and
CAM2 are provided on the rear panel for separate camera
video inputs. The input connectors, the top BNC's of the pairs,
are terminated in either 75 ohms or HiZ, selectable by an
internal jumper switch (see Internal Setup). Below each input
BNC is a loop-through video output BNC connector.
Satisfactory motion detection requires that the video signals be
CONSIDERATIONS, for further discussion of video inputs.

Video Outputs

Two BNC connectors labeled OUTPUT 1 and 2 are provided
on the rear panel. The outputs provide a composite video
signal of 1V p-p. Each output must be terminated in 75 ohms.
The outputs function differently depending on the setup
configuration. The Number of Monitors option (SETUP, page
of these outputs. Video Output 1 is also used for the setup
menus (SETUP, page 4).
Alarm
Outputs
A 6-pin connector labeled ALARM OUTPUTS is provided on
the rear panel for access to an internal alarm relay and two
logic-level alarm closures that are active during alarms.
The alarm relay has Form C contacts for the control of external
devices during alarms. The contact rating for this relay is: 1A
circuits, such as remote callup of a switcher or control of an
The pin definitions of this connector are:
Function
1
2
Alarm Relay NO (Normally Open)
Alarm Relay Common
3
4
Alarm Relay NC (Normally Closed)
5
6