Verifying The Ethernet Connection - Alvarion BreezeACCESS 900 System Manual

Broadband wireless access system
Hide thumbs Also See for BreezeACCESS 900:
Table of Contents

Advertisement

Chapter 3 - Commissioning

Verifying the Ethernet Connection

Once you have connected the unit to a PC (SU-I) or to the network (AU),
verify that the Ethernet Integrity indicator (the yellow LED embedded in
the Ethernet connector) is on, indicating that the unit is connected to
an Ethernet segment. The Ethernet Activity indicator (the green
embedded LED) should blink whenever the unit receives or transmits
traffic on the Ethernet port.
Verifying Data Connectivity (SU-I)
To verify data connectivity, from the end-user's PC or from a portable
PC connected to the unit, ping the primary Access Unit, or try to
connect to the Internet.
Verifying Proper Operation of the
GU-A-BS GPS Unit
When the unit is operating properly, the PWR and OK green LEDS
should be on, indicating that the BS-GU module is supplying power to
the GU-RA GPS antenna and that the GPS antenna is functioning
properly.
NOTE
It may take up to 10 minutes from the time the GU-RA GPS antenna is powered up
until it is fully synchronized with the GPS satellite system.
If the OK LED is not on, check the functionality of the GPS antenna as
follows:
1. From the Main Menu, select Info Screens. The Info Screens menu
opens.
2. From the Info Screen menu, select Show Unit Status and view the
Unit Status display. You should see one of the following messages:
3-18