12
Appendix C – Pedestal requirements
Any pedestal solution designed for Terra DC Wallbox needs to fulfill the specific ISO standards for civil
constructions (note: specific local regulations may apply).
Additionally, whereas no specific constraint is provided by local regulations, the minimum set of re-
quirements necessary to provide a safe installation are listed in the table below to be verified in the
temperature range between -50°C - +60°C:
Minimum Wind load resistance
Minimum compression load capability (applied on center of
mass of the WB)
Side / Back / frontal impact MAX (applied on the pedestal/WB)
higher point
Pulling /Pushing force applied (to gun holders if they are me-
chanically connected to same structure and external to the WB
area)
Min / Max distance of gun holder from WB (if mechanically con-
nected to pedestal structure)
Rust protection paint
Minimum clearance areas side / top / bottom around the
charger
Recommended foundation requirements (min tilting torque)
Vibration test required on the full system
Electrical ground connection
Revision Level
2.1
20 2 0- 10- 05
Change
Added revision level to document and
added revision table
T ER R A DC WA LL BOX U L
100km/h
4kN
3kN
3kN
300mm / 1000mm
Yes
300mm
To be designed con-
sidering the max
loads in each direc-
tion
According to proce-
dure described in
IEC 60068-2-27:
2008 and IEC
60068-2-6: 2007
To the chassis of the
DCWB
Date
4-15-2021
3 8/ 3 8