10. Deleting all settings (reset)

A reset can be carried out to reset the DuoFern Tubular Motor
Actuator 9471-1 to the default factory settings.
1.
2.
All of the settings are deleted and reset to the default factory set-
tings and the logged-on DuoFern transmitters are automatically
logged off.
3.
The DuoFern Tubular Motor Actuator 9471-1 is then reset to the
default factory settings.
i

11. Dismantling

There is a risk of fatal electric shock when touching electri-
cal components.
◆ Disconnect all phases of the mains power lead and secure
it to prevent any reconnection. Check that the system is
de-energised.
1.
Log the DuoFern Tubular Motor Actuator 9471-1 off from the
DuoFern network.
2.
Ensure the mains power is current-free and open the flush-mount-
ed box.
3.
Disconnect the DuoFern Tubular Motor Actuator 9471-1 and
completely remove it from the flush-mounted box.
Press and hold the disconnect button for approx.
5 seconds until the STATUS LED constantly lights
up red.
DANGER!