6. BASIC INSTRUCTIONS
Before
execution
FMOV
(1) Program which outputs the data of the lower 4 bits of D0 to Y10 to 23 in units of
4 points when XA turn on.
Ignored
X00A
P
0
FMOV
(2) Program which outputs the data of X20 to X23 to D100 to D103 when XA is
turned on.
Ignored.
X00A
P
0
FMOV
(S)
Transfer
K1
K
D0
Y010
5
After execution (destination)
Turn to 0.
K1
K
X020
D100
4
6 − 55
MELSEC-A
(D)
• Coding
0
LD
X00A
1
FMOVP D0
K1Y010
10
END
• Coding
0
LD
X00A
1
FMOVP K1X020 D100
10
END