Help Text Overview - PR 4222 Product Manual

Universal i/f converter
Hide thumbs Also See for 4222:
Table of Contents

Advertisement

[01]
Set correct password
[02]
Enter advanced setup menu?
[03]
Select temperature input
Select potentiometer input
Select linear resistance input
Select current input
Select voltage input
[04]
Select 0.0-1 V input range
Select 0.2-1 V input range
Select 0-2.5 V input range
Select 0.5-2.5 V input range
Select 0-5 V input range
Select 1-5 V input range
Select 0-10 V input range
Select 2-10 V input range
[05]
Select 0-20 mA input range
Select 4-20 mA input range
[06]
Select 2-wire sensor connection
Select 3-wire sensor connection
Select 4-wire sensor connection
[07]
Set 0% resistance value
[08]
Set 100% resistance value
[09]
Select Celsius as temperature unit
Select Fahrenheit as temperature unit
[10]
Select TC sensor type
Select Ni sensor type
Select Pt sensor type
[11]
Select display unit
[12]
Select decimal point position
[13]
Set display readout low
[14]
Set display readout high
[16]
Select Pt10 as sensor type
Select Pt20 as sensor type
Select Pt50 as sensor type
Select Pt100 as sensor type
Select Pt200 as sensor type
Select Pt250 as sensor type
Select Pt300 as sensor type
Select Pt400 as sensor type
Select Pt500 as sensor type
Select Pt1000 as sensor type
[17]
Select Ni50 as sensor type
Select Ni100 as sensor type
Select Ni120 as sensor type
Select Ni1000 as sensor type
[18]
Select TC-B as sensor type
Select TC-E as sensor type
Select TC-J as sensor type
Select TC-K as sensor type
Select TC-L as sensor type
Select TC-N as sensor type
Select TC-R as sensor type
Select TC-S as sensor type
Select TC-T as sensor type
Select TC-U as sensor type
Select TC-W3 as sensor type
24

Help text overview

Select TC-W5 as sensor type
Select TC-Lr as sensor type
[19]
Select 50% duty cycle output
Select programmable pulse time
[20]
Select Hz as output unit
Select pulses/minute as output unit
Select pulses/hour as output unit
Select pulses/day as output unit
[21]
Set output frequency for 0% input
[22]
Set output frequency for 100% input
[23]
Set low cut-off frequency
[24]
Set pulse time in milliseconds
[25]
Select no error action - output undefined at error
Set output at specific frequency on input error
[26]
Set output frequency on input error
[40]
Set response time in seconds
[41]
Set temperature for frequency output low
[42]
Set temperature for frequency output high
[43]
Enter language setup
Enter password setup
Enter simulation mode
Perform process calibration
Enter display setup
Perform memory operations
[44]
Load saved configuration into module
Save configuration in display front
[45]
Adjust LCD contrast
[46]
Adjust LCD backlight
[47]
Write a 6-character device TAG
[48]
Output frequency is shown in display line 3
Device TAG is shown in display line 3
[49]
Calibrate input low to process value?
[50]
Calibrate input high to process value?
[51]
Enter simulation mode?
[52]
Simulate input value
[54]
Enable password protection?
[55]
Set new password
[59]
Select language
[60]
Use process calibration values?
[61]
Set value for low calibration point
[62]
Set value for high calibration point
4222V101-UK