Summary of Contents for Pickering PXI 40-535

  • Page 1 (217) 352-9330 | Click HERE Find the Pickering 40-536-021 at our website:...
  • Page 2 40-535/536/537 User Manual PXI Ultra High Density Matrix Module pickeringtest.com Issue 5.1 February 2020...
  • Page 3 © COPYRIGHT (2020) PICKERING INTERFACES. ALL RIGHTS RESERVED. No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by any means without the written permission of Pickering Interfaces. Technical details contained within this publication are subject to change without notice.
  • Page 4 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
  • Page 5: Product Safety

    PRODUCT SAFETY SAFETY SYMBOLS The following safety symbols may be used on the product and throughout the product documentation. MEANING / DESCRIPTION SYMBOL PROTECTIVE EARTH (GROUND) To identify any terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal of a protective earth (ground) electrode.
  • Page 6: Table Of Contents

    Pre Operation Checks ............3.1 Hardware Installation ............3.2 Software Installation .............3.2 Testing Operation ..............3.3 Section 4 Programming Guide ..............4.1 Programming Options For Pickering PXI Modules ....4.1 Module Architecture ..............4.2 Programming The Module ............4.3 Section 5 Connector Information ..............5.1 Section 6 Trouble Shooting .................6.1 Section 7 Maintenance Information ............7.1...
  • Page 7 THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page (VI)
  • Page 8: Warnings And Cautions

    Not to be used in safety critical circuits, refer to the Pickering Interfaces’ terms & conditions of sale. This module must not be used for the switching of Mains Circuits. For the switching of voltages up to the module’s full specification, Secondary Circuit power supplies and the Device Under Test must...
  • Page 9 CAUTION - PRODUCT DOCUMENTATION SYMBOL Suitably qualified & trained users should ensure that the accompanying documentation is fully read and understood before attempting to install or operate the product. SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS All cleaning and servicing requires the equipment to be isolated and disconnected from the power source and user I/O signals (refer to the Maintenance Section).
  • Page 10: Technical Specification

    • Supported by eBIRST ™ signals from multiple modules. However, for applications that • 3 Year Warranty require a very large matrix, Pickering’s BRIC™ modules are best suited. The 40-535/536/537 are ultra high density PXI switching matrices constructed with reed relays. The range is as follows: Supported by eBIRST •...
  • Page 11 Connectors All reed relays are manufactured by our sister company Pickering PXI bus via 32-bit P1/J1 backplane connector. Electronics: pickeringrelay.com Signals via front panel 96-pin male micro-D connector, for pin outs please refer to the operating manual.
  • Page 12 For more information go to: pickeringtest.com/ebirst Product Customization Product Test Tool Adaptor Termination Pickering PXI modules are designed and manufactured on our own 40-535/6/7 93-002-001 93-002-226 93-016-103 flexible manufacturing lines, giving complete product control and Spare Relay Kits enabling simple customization to meet very specific requirements.
  • Page 13 We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
  • Page 14 Ultra High Density Matrix – 40-535/536/537 Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
  • Page 15 SECTION 1 - TECHNICAL SPECIFICATION pickering THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 1.6...
  • Page 16: Functional Description

    SECTION 2 - TECHNICAL DESCRIPTION pickering SECTION 2 - TECHNICAL DESCRIPTION FUNCTIONAL DESCRIPTION A functional block diagram is provided in Figure 2.1. The Ultra High Density Matrix Module is powered by a +5V input via Compact PCI connector J1. The interface to the user test equipment is via the front panel mounted 96-pin micro-D connector, J2.
  • Page 17 SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 2.2...
  • Page 18: Installation

    Modular products require installation in a suitable PXI/LXI chassis. The module is designed for indoor use only. PREOPERATION CHECKS (UNPACKING) 1. Check the module for transport damage and report any damage immediately to Pickering Interfaces. Do not attempt to install the product if any damage is evident.
  • Page 19: Hardware Installation

    For a system comprising more than one chassis, turn ON the last chassis in the system followed by the penultimate, etc, and finally turn ON the external controller or chassis containing the system controller. 9. For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up sequence.
  • Page 20: Testing Operation

    Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
  • Page 21 SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 3.4...
  • Page 22: Programming Guide

    SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
  • Page 23: Module Architecture

    SECTION 4 - PROGRAMMING GUIDE pickering MODULE ARCHITECTURE The 40-535 is a single 1-pole switching matrix with 92 connections on the X-axis and 4 connections on the Y-axis. Connections are made by operating the relays at the crosspoints between X and Y lines allowing single X-Y connections, or X-X connections using a Y line as a path.
  • Page 24: Programming The Module

    Once the drivers are installed the manual “Sys40Prg.pdf” and driver help files which fully describes these functions can be found in the Pickering folder(s) or the Pickering entries on your Start Menu. The card must be opened before use and closed after using the following function calls: Direct I/O Driver - Open with PIL_OpenCards or PIL_OpenSpecifiedCard and close with PIL_CloseCards or PIL_CloseSpecifiedCards respectively.
  • Page 25 SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 4.4...
  • Page 26: Connector Information

    SECTION 5 - CONNECTOR INFORMATION pickering SECTION 5 - CONNECTOR INFORMATION Figure 5.1 - Pinout: 40-535-021 Single 1-Pole 92x4 Ultra High Density Matrix Module (96-pin male micro-D connector viewed from front of module) ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 5.1...
  • Page 27 SECTION 5 - CONNECTOR INFORMATION pickering X101 X102 X103 X104 X105 X106 X107 X108 X109 X110 X111 X112 X113 X114 X115 X116 X117 X118 X119 X120 X121 X122 X123 X124 X125 X126 X127 X128 X129 X130 X132 X131 X134 X133...
  • Page 28 SECTION 5 - CONNECTOR INFORMATION pickering Figure 5.3 - Pinout: 40-537-021 & 40-537-021-S Single 1-Pole 44x8 Ultra High Density Matrix Module (96-pin male micro-D connector viewed from front of module) Note: On the screened version, reed relay screen is connected to the the front panel ground (GND).
  • Page 29 SECTION 5 - CONNECTOR INFORMATION pickering THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 5.4...
  • Page 30: Trouble Shooting

    PCI configuration, highlighting any potential configuration problems. Specific details of all installed Pickering switch cards are included. All the installed Pickering switch cards should be listed in the “Pilpxi information” section - if one or more cards is missing it may be possible to determine the reason by referring to the PCI configuration dump contained in the report, but interpretation of this information is far from straightforward, and the best course is to contact Pickering support: support@pickeringtest.com, if possible...
  • Page 31 SECTION 6 - TROUBLE SHOOTING pickering THIS PAGE INTENTIONALLY BLANK ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 6.2...
  • Page 32: Maintenance Information

    For PXI modules which are supported in one of Pickering Interfaces’ Modular LXI Chassis (such as the 60-102B and 60-103B) no module software update is required. If the module was introduced after the LXI chassis was manufactured the module may not be recognized, in this case the chassis firmware may need upgrading.
  • Page 33 SECTION 7 - MAINTENANCE INFORMATION pickering RELAY LOOK-UP TABLES NOTE: Relays on the motherboard are highlighted in blue and relays on the daughterboard are highlighted in yellow. TABLE 7.1 - 92x4 Ultra High Density Matrix 40-535-021 Relay Numbering - Motherboard...
  • Page 34 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.2 - 92x4 Ultra High Density Matrix 40-535-021 Relay Numbering - Daughterboard Matrix Matrix Matrix Matrix Relay Relay Relay Relay Crosspoint Crosspoint Crosspoint Crosspoint ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 7.3...
  • Page 35 SECTION 7 - MAINTENANCE INFORMATION pickering RL47 RL93 RL139 RL24 RL70 RL116 RL162 RL48 RL94 RL140 RL25 RL71 RL117 RL163 RL49 RL95 RL141 RL26 RL72 RL118 RL164 RL50 RL96 RL142 RL27 RL73 RL119 RL165 RL51 RL97 RL143 RL28 RL74 RL120...
  • Page 36 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.3 - Dual44x4 Ultra High Density Matrix 40-536-021 Relay Numbering - Motherboard Matrix Matrix Matrix Matrix Relay Relay Relay Relay Crosspoint Crosspoint Crosspoint Crosspoint — — — — — — — — —...
  • Page 37 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.4 - Dual 92x4 Ultra High Density Matrix 40-536-021 Relay Numbering - Daughterboard Matrix Matrix Matrix Matrix Relay Relay Relay Relay Crosspoint Crosspoint Crosspoint Crosspoint — — — — — — — —...
  • Page 38 SECTION 7 - MAINTENANCE INFORMATION pickering RL47 RL93 RL139 RL24 RL70 RL116 RL162 RL48 RL94 RL140 RL25 RL71 RL117 RL163 RL49 RL95 RL141 RL26 RL72 RL118 RL164 RL50 RL96 RL142 RL27 RL73 RL119 RL165 RL51 RL97 RL143 RL28 RL74 RL120...
  • Page 39 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.5 - 44x8 Ultra High Density Matrix 40-537 Relay Numbering - Motherboard Matrix Matrix Matrix Matrix Relay Relay Relay Relay Crosspoint Crosspoint Crosspoint Crosspoint ULTRA HIGH DENSITY MATRIX MODULE 40-535/536/537 Page 7.8...
  • Page 40 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.6 - 44x8 Ultra High Density Matrix 40-537 Relay Numbering - Daughterboard Matrix Matrix Matrix Matrix Matrix Relay Relay Relay Relay Relay Crosspoint Crosspoint Crosspoint Crosspoint Crosspoint — — — — — —...
  • Page 41 SECTION 7 - MAINTENANCE INFORMATION pickering RL16 RL15 RL14 RL13 RL12 RL11 RL10 RL24 RL23 RL22 RL21 RL20 RL19 RL18 RL17 RL32 RL31 RL30 RL29 RL28 RL27 RL26 RL25 RL40 RL39 RL38 RL37 RL36 RL35 RL34 RL33 RL48 RL47 RL46...

Table of Contents