Installation
Changing the Orientation of the Fluid Inlet
and Outlet Ports
The pump is shipped with the fluid inlet (R) and outlet
(S) ports facing the same direction. See F
change the orientation of the inlet and/or outlet port:
1. Remove the screws (106 and 112) holding the inlet
(102) and/or outlet (103) manifold to the covers
(101).
2. Reverse the manifold and reattach. Install the
screws and torque to 9-10 N•m. See Torque
Sequence, page 30.
KEY
N 1/2 npt(f) Air Inlet Port
P Muffler; Air Exhaust Port is
3/4 npt(f)
R 1-1/2 in. Fluid Inlet DIN 40
Flange
S 1-1/2 in. Fluid Outlet DIN
40 Flange
N
P
102
Fig. 4 ______________________________________
. 4. To
IG
101 Fluid Covers
102 Fluid Inlet Manifold
103 Fluid Outlet Manifold
106 Fluid Outlet Manifold
Screws (Top)
112 Fluid Inlet Manifold
Screws (Bottom)
1
Torque to 9-10 N•m. See Torque
Sequence, page 30.
103
106
1
112
1
Fluid Pressure Relief Valve
Some systems may require installation of a pressure
relief valve at the pump outlet to prevent
overpressurization and rupture of the pump or hose.
See F
. 5.
IG
Thermal expansion of fluid in the outlet line can cause
overpressurization. This can occur when using long
fluid lines exposed to sunlight or ambient heat, or when
pumping from a cool to a warm area (for example, from
an underground tank).
Overpressurization can also occur if the VERDERAIR
VA 40 pump is being used to feed fluid to a piston
pump, and the intake valve of the piston pump does not
close, causing fluid to back up in the outlet line.
KEY
R
1-1/2 in. Fluid Inlet DIN 40 Flange
S
1-1/2 in. Fluid Outlet DIN 40 Flange
V
Pressure Relief Valve
Part No. 819.0159 (Stainless Steel)
1
Install valve between fluid inlet and outlet ports
2
Connect fluid inlet line here.
S
3
Connect fluid outlet line here.
101
R
Fig. 5 ______________________________________