Reason: 50 hours have gone by since oil was last
changed, and you must check its level.
How to turn it off: once you have checked the level,
press the partial counter push-button (fig. 21 ref. 9).
Keep it pressed, then turn the panel on and release the
push-button when the unit has started up.
Alarm: the red maintenance lamp is lighted.
Reason: 100 hours have gone by since oil was changed.
The oil must be replaced.
How to turn it off:Once you have changed the oil, turn
the panel on and make sure the generating set is running.
Now press the push-button hidden under the bottom right
(fig. 21 rif. 10), then release it at once. wait two minutes
before turning the unit off.
Under special conditions, the data contained in
the micropocessor inside the panel can undergo
alterations. This may be because the battery is
very low, or because the cables used to connect
the battery to the unit have too small a cross-
section. In this case, the alteration of the data
may prevent the unit from running. In order to
make the unit work again properly, proceed as
follows:
Alarm: meaningless characters appear on the display.
Reason: malfunction due to low voltage during start-up
(battery very low, cable cross-section too small).
Reinitialise the panel.
How to turn it off: press the hidden push-button; keep it
pressed while turning on the panel. Release the push-
button when 4 zeros (0000) appear on the panel The
panel has been reinitialised.
ROUTINE MAINTENANCE SCHEDULE
To be performed after the period of time or the number of
running hours listed here, whichever the earlier may be.
Engine oil
Air filter
Spark plug
Valve adjustment
Tank and fuel filter.
Engine r.p.m.'s or frequency
Vibration damper suspension points
Fuel pipes
NOTES: (1) Clean more frequently if you use it in a very dusty environment.
(2) These operations must be performed by specialised personnel only
16
GB

7 MAINTENANCE INSTRUCTIONS

parts. T he use of spare parts of non-
equivalent
generating set.
Routine control and adjustments are of the
essence in preserving a high level of
performance.
ensures long generating set life.
check or maintenance operation on the
generating set, turn the selector switch (Fig.
22 ref. 2) to the position 1 "manual" in order
to avoid accidentally starting the generating
set up.

7.1 Maintenance list

See table at the bottom of the page.
7.2
personnel
To perform this kind of operation, it will be
necessary to open the door of the generating set.
The following precautions must therefore be
taken:
1) The generating set must not be running, and
all its parts must be cold
2) Let the generating set cool off.
3) Turn the selector switch to the position "1"
(manual) (Fig. 22 ref. 2)
N.B. Remember to put the selector switch
back at "0" (automatic) when you have
finished the operation.

7.3 Checking the engine oil level

Inspection
Change
Cleaning
Inspection-cleaning
Check-adjust
Cleaning
Adjust
Check
Check
(replace
if
necessary)
Energy 4000 B / 4000 GAS
Use only original spare
quality
Routine
Before performing any
Maintenance not requiring specialised
Every
Every use
month or
20 h
(2)
(1) ● (2)
(2)
Ogni due anni
may
damage
the
maintenance
also
Every 6
Every year
month or
or 300 h
100 h
(2)
(2)
(2)
(2)
(2)
Vers. 013