7.3.1 Automatic Version (optional)

If you wish the start-up batteries to be recharged
automatically in the En 4010D generating sets, it
is possible to install the ASP (optional) automatic
control panel
(fig. 25) instead of the manual
c
ontrol panel.
T
he elements making it up are:
1
ON/OFF
switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicat
5 Start-up failed indicator
6 Generator running indicator (fla
7 Maintenance request in
8 Fuel reserve indicator
9 Hour or
voltmetric changeover switch button
10 Reset
11 Battery charged indicator
12 Automatic function indicator
13
AUTO/MAN swi
tch for the automatic or
manual function
7.4 MANUAL o
peration
S
ee section 7.3
7

.4.1 AUTOMATIC operation

Turn the AUTO/MAN switch (fig. 25 ref. 13) to the
AUTO position and set
re
f. 1) to ON position.
16
or
shing)
dicator
the start-up switch (fig. 25
Energy 4010 D
GB
The automatic function indicator (fig. 25 ref. 12)
will light up. If the battery which supplies the
g
enerating set has a voltage of more than 11.5
Volts, the batter
y charged indicator (fig. 27 ref.
11) will light up.
When the voltage at the ends of the 12V DC
terminals of the generating set is lower than 11.5
Volts, the battery charged light indicator (fig. 27
ref. 11) will go off and the generating set will
begin the start-up pr

manual operation).

During the operation in automatic mode, the
display (fig. 25 rif. 2) will show the total running
hours of the generating set. Press the hour or
voltmetric changeover switch button (fig. 25 ref.
9) to display the voltage at the ends of the
DC terminals, i.e. at the ends of the battery.
When the battery is charged, and anyway after at
least 15 minutes' running, the battery charged
hours indicator (page 25 ref. 11) will light up and
the electronic
control panel will turn off the
g
enerating set.
automatic position after turning the control
panel on sets the generating set in stand-by
mode and does NOT activate the automatic
fu
nction.
Remember that the time which is taken by
the generating set in automatic mode to
recharge the battery may vary according to
the battery status, the amount of conn
batteries and the season temperature.
Generally, the lower the temperature the
th
e time required to charge the battery.
than the energy just then available in the
battery will prevent the generating set from
tu
rning on due to insufficient voltage.
8

MAINTENANCE INSTRUCTIONS

ocedure (similar to that of the
Setting the switch to the
Applying any load higher
Vers. 001
12V
ected
less