Installation and User Guide
4.4

Control modes, special functions, special statuses and settings

Each of 7 Channels has possibility to be individually set up with one of three control
modes – 1S (1 Sensor), PR (Power Regulation) and MOn/MOf (Manually On/Of) .
The controller configurations for these 3 modes are the following:
1 .
Single sensor control with temperature sensor or 1S: one temperature sensor input,
one relay output;
2 .
Power regulation control or time proportional power regulation or PR: no sensor
input, one relay output;
Heating control Manually On and Manually Off with setting time period or MOn and
3 .
MOf: no sensor input, one relay output;
Together with any control mode could be set up or enabled/disabled some special functions
and statuses: "Relay status RO/RC", "CableOK?", "Relay test 5/30", "Channel ON/OFF" and
"Device ON/OFF" . Special functions and statuses are specified in chapters below .
Additionally, any Channel can be set up with status 'not Active' or Active = No . It means
Channel does not work at all and "empty" line appears on the Main Screen .
4.4.1

Active and Not Active Channel status

Not Active status can be used for applications there is no need to use full channel set of 7 .
And view/line for the Channel which is not used is simply deleted from the screen .
By the way, standard factory setting for DEVIreg™ Multi supposes 1 active Channel #2 .
The Main Screen with the only one Active Channel #2 is as on the picture below: