8. MAINTENANCE AND CLEANING.

WARNING! Any equipment repair must be
performed
Improper repairs can put the user in
serious danger. If your equipment needs
to
be
repaired,
technical assistance service.
WARNING!
maintenance operation, make sure that
the equipment is not and cannot be
accidentally connected to the power
supply.
equipment
supply
maintenance or cleaning activities.

8.1 Resetting of safety equipment

The device is equipped with a safety thermostat. When
manually reset, the equipment is tripped in case of over-
heating.
In order to reset the protection it is necessary to:
Disconnect the device from the mains power
supply;
Remove any air ducts (see paragraph 5.2);
Remove the upper cover by undoing the
appropriate locking screws (Fig. 17);
Manually reset the tripped safety thermostat from
the top (Fig. 18). In the event of the trip- ping, the
central
pin
of
the
approxTESYely 4 mm;
Reassemble the upper cover that was previously
removed
by
qualified
personnel.
please
contact
Before
attempting
Therefore,
disconnect
from
the
mains
before
carrying
out
thermostat
sticks
the
any
the
power
any
out
by

8.2 Quarterly inspections

Visual inspection of the general conditions of the
equipment systems as well as the absence of leaks;
Inspection of the ventilation filter (see paragraph
8.4).

8.3 Annual inspections

Inspection of the tightness of bolts, nuts, flanges
and water supply connections that may have been
loosened by vibration;
Check the state of integrity of the magnesium
anodes (see paragraph 8.5).

8.4 Cleaning of the ventilation filter

In the upper part of the equipment there is a ventilation
filter. This must be periodically cleaned in order to
maintain the perfect efficiency of the system.
After every 1000 hours of operation, the display of the
equipment shows the "FiL" alarm that indicates the need
to check the cleanliness of the filter.
To remove the filter, it is necessary to grab it with the
fingers from the dedicated side opening and pull it outside
(Fig. 19).
Page 24 of 28
WARNING! The tripping of the sfety
thermostat can be caused by a fault
linked to the control board or by the
absence of water inside the tank.
WARNING!
Carrying
operations on parts that perform
safety functions jeopardises the safe
operation of the equipment. Substitute
the faulty elements only with original
spare parts.
N.B.:
The
intervention
thermostat excludes the operation of
the electric heating elements but not
the heat pump system within the
permitted operating limits.
out
repair
of
the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evhp 7s 260 60Evhp 7s 200 60Evhp 260 60Evhp 200 60