Parameter description
Display data refresh time specified in tenths
of a second
Work set hysteresis
Minimum auto cycle set point
Maximum auto cycle set point
Minimum economy cycle set point
Maximum economy cycle set point
Work set change block
Delay in equipment start-up
Delay as from last ON
Delay as from last OFF
Minimum ON time
Number of compressor operating hours
required for maintenance
Delay air temperature sample taking for cold
evaporator test
Minimum delay between fan start-up and
compressor activation for incoming air
temperature check
Timeout GREEN cycle
Delay for damaged fan check
Type of defrosting
Evaporator temperature to conclude
defrosting procedure (only if P4=1)
Maximum duration of defrosting procedure
Automatic
defrosting
(evaporator temperature)
Minimum compressor start up time to start
defrosting procedure
Minimum level probe alarm (only AL1
warning)
Minimum alarm set (only AL1 warning)
Type of minimum level alarm delay (only
AL1 warning)
Maximum level probe alarm (only AH
warning)
Maximum alarm set(only AH warning)
Type of maximum level alarm delay (only AH
warning)
Minimum level AL1 alarm delay due to
equipment start-up (only warning)
AL1 and AH temperature alarm delays
(only warning)
Alarm hysteresis
Heating element start-up interval (Anti-
Legionella)
Anti-Legionella function set
Duration of Anti-Legionella function
Digital 1 input enabling
Type of digital 1 input contact
High/low pressure end compressor protection
Code
P8
r0
r1
r2
r3
r4
r5
C0
C1
C2
C3
C10
C11
C12
C13
C14
d1
d2
d3
start
threshold
d17
d18
A0
A1
A2
A3
A4
A5
A6
A7
A11
H0
H1
H3
i0
i1
i2
Page 22 of 28
U.M.
Min
Max
1/10
0
250
sec
°C/°F
0.1
30.0
°C/°F
10.0
r2
°C/°F
r1
100.0
°C/°F
10.0
r4
°C/°F
r3
100.0
----
0
1
min
0
240
min
0
240
min
0
240
sec
0
240
h
0
9999
min
0
999
min
0
240
min
0
240
min
-1
240
----
0
2
°C/°F
-50.0
50.0
min
0
99
°C/°F
-50.0
50.0
min
0
240
----
0
2
°C/°F
0.0
50.0
----
0
1
----
0
2
°C/°F
0.0
199.0
----
0
1
min
0
240
min
0
240
min
0.1
30.0
days
0
99
°C/°F
10.0
199.0
min
0
240
----
0
2
----
0
1
min
0
120
Default
Notes
5
7.0
40.0
70.0
40.0
(56°C for L versions)
62.0
1 = It is not possible to
0
change the set point; it can
only be seen
5
Compressor protections
5
5
0
1000
0 = Function excluded
120
1
20
20
-1 = disabled function
0 = With heating element
1 = With hot gas
1
2 = With compressor
stopped
25.0
8
-2.0
60
0 = Upper probe
1 = Lower probe
0
2 = Evaporator probe
10.0
0 = Disabled
0
1 = Absolute
0 = Upper probe
1 = Lower probe
0
2 = Evaporator probe
90.0
0 = Disabled
0
1 = Absolute
120
15
2.0
30
70.0
2
0 = Input disabled
1 = Pressure input
2
2 = GREEN input
0 = Active if contact is
closed
0
1= Active if contact is open
0