3. Installation

3.1. Space requirements

You can install the machine on any suitable and even floor (concrete) in a factory hall. Observe the allowed floor load. The machine
should be aligned using the underlay sheets under the base anchors (not included in the shipment).
While preparing the cutting, the operating staff is allowed to move around the machine only when the machine is not running. When
the machine is running, the operator has to stay only at the control panel so that he/she is able to switch off the machine any time. The
operator must also ensure that no other persons are present in or near the working area of the machine. No unauthorised personnel
in the hazard space. To prevent injury, the danger zone must also be level and free from any foreign objects and obstacles.
Recommendations / requirements:
• Allow for sufficient space for the feeding and removal of the workpiece and the machine maintenance - the operator's working area
should be delineated at 1 m minimum around the machine and 0.5 m around the roller conveyors.
• In order to ensure safe handling of workpieces and protection of the space behind the cut from falling cut-off pieces, one or more
roller conveyors must be installed, possibly a container for falling cut workpieces.
• Install a lift mechanism for heavy workpieces.
• Ensure proper lighting at the workplace.
DANGER ZONE LIMITS
1 m
0,5 m
0,5 m
0,5 m
0,5 m
1 m