4.6.2. Removal of protective covers of the saw blade in ARG 380, 500 plus S.A.F.
Connect the machine to the mains and press the POWER SWITCH. The TOTAL STOP button is unlocked. Start the MANUAL
MODE, switch on the HYDRAULIC UNIT - START. Switch the ARM END STROKE SWITCH into position 0 in order to control fully the
arm movement via the touch screen. Raise the arm into the upper position by pressing the SAW BLADE UPWARDS button and stop
the uplift by pressing the STOP button on the display. Shut off the CONTROL VALVE completely (see section 4.2.). Start the saw arm
descent and by gradually releasing the CONTROL VALVE move the arm to about 50mm above the fixed jaw of the vice and close the
CONTROL VALVE. Close the vice so that the cover of the front moving block slides from the front part of the arm - tensioning wheel.
Switch off the POWER SWITCH and secure it against restart. Open the covers A, then flip up covers B, C and unscrew the cover D.
Mount back the covers using reverse procedure. Turn on the POWER SWITCH and the hydraulic unit.
S.A. MODE - the arm is situated in between the limit switches, therefore it is necessary to switch the ARM END STROKE SWITCH
into position 1 and the arm will travel to the upper position. Now you can start cutting and the descent; press the green button START
and the semi-automatic cycle will start.
MANUAL MODE - press the SAW BLADE UPWARDS button and the arm will also travel into the upper position; or press the SAW
BLADE DOWNWARDS button and the arm will travel to the lower position (ARM END STROKE SWITCH must be set in position 0).