Unit Start Up
Table 47. Return fan performance—60, 70, 75 tons AC; 73, 80, 89 tons EC (36.5" fan)
CFM
Std.
0.25
Air
RPM
BHP
RPM
12000
459
1.07
502
13000
490
1.27
530
14000
520
1.49
560
15000
552
1.73
590
16000
583
2.00
619
17000
615
2.30
650
18000
646
2.64
680
19000
678
3.01
711
20000
711
3.42
742
21000
743
3.87
773
22000
775
4.36
805
23000
808
4.89
836
24000
840
5.46
868
25000
873
6.08
900
26000
906
6.75
931
27000
939
7.47
963
Notes:
1. Max fan RPM 1151 for 36.5" Class I Fan
2. Max motor available 20 HP for 36.5" fan size
3. Max motor available 20 HP for 60, 70 & 75T/ 73, 80 & 89T
4. Max CFM is 27000 for 60, 70 & 75T/ 73, 80 & 89T
5. Min CFM is 12000 for 60, 70 & 75T/ 73, 80 & 89T
6. Return fan belt drive RPM selections will be available to cover 500-1100 RPM range +/- 50 RPM
7. Performance data includes cabinet and rain hood effect. Damper pressure drop will have to be added to return duct static per table

Economizer Damper Adjustment

Exhaust Air Dampers
Verify that the exhaust dampers (if equipped) close tightly when the unit is off. Adjust the damper
linkage as necessary to ensure proper closure. An access panel is provided under each damper
assembly.
Fresh Air & Return Air Damper Operation
The fresh air and return air damper linkage is accessible from the filter section of the unit. The
damper linkage connecting the fresh air dampers to the return air dampers is preset from the
factory in the number 1 position. Refer to
and operating airflow (CFM).
No Step Surface!
Do not walk on the sheet metal drain pan. Walking on the drain pan could cause the
supporting metal to collapse, resulting in the operator/technician to fall. Failure to follow this
recommendation could result in death or serious injury.
Note: Bridging between the unit's main supports may consist of multiple 2 by 12 boards or sheet
Arbitrarily adjusting the fresh air dampers to open fully when the return air dampers are closed or;
failing to maintain the return air pressure drop with the fresh air dampers when the return air
132
Negative Static Pressure
0.50
0.75
BHP
RPM
BHP
RPM
1.59
541
2.13
1.83
567
2.40
2.09
595
2.70
2.38
623
3.03
2.70
652
3.39
3.05
681
3.78
3.43
711
4.20
3.85
741
4.67
4.30
771
5.17
4.78
801
5.70
5.31
832
6.28
5.88
863
6.90
6.49
894
7.56
7.15
925
8.26
7.86
956
9.00
8.62
987
9.79
1010
metal grating.
1.00
1.25
BHP
RPM
BHP
578
2.71
613
3.31
603
3.01
636
3.65
628
3.34
660
3.99
655
3.70
686
4.39
682
4.09
712
4.82
710
4.52
739
5.28
739
4.98
766
5.78
768
5.48
794
6.31
797
6.02
823
6.90
827
6.60
852
7.51
857
7.22
881
8.17
887
7.89
911
8.88
918
8.60
941
9.63
948
9.35
970
10.42
979
10.16
1001
11.28
11.01
1031
12.18
Table 48
for the appropriate linkage position for the unit
WARNING
1.50
1.75
RPM
BHP
RPM
BHP
647
3.91
681
4.54
668
4.29
700
4.94
691
4.69
721
5.38
715
5.11
744
5.85
740
5.57
767
6.34
766
6.06
792
6.85
792
6.60
817
7.41
819
7.16
844
8.03
847
7.77
871
8.66
875
8.41
898
9.36
904
9.11
926
10.09
933
9.87
954
10.86
962
10.67
983
11.71
992
11.49
1012
12.59
1021
12.37
1041
13.49
1052
13.33
1071
14.47
2.00
RPM
BHP
713
5.20
731
5.64
751
6.10
771
6.59
794
7.14
818
7.67
842
8.27
867
8.89
894
9.59
920
10.30
947
11.06
975
11.88
1004
12.75
1032
13.67
1061
14.63
1090
15.65
Table 40, p. 126