Trane IntelliPak SAHL Series Installation, Operation And Maintenance Manual page 176

Commercial single-zone rooftop air conditioners with cv, vav, or szvav controls
Table of Contents

Advertisement

Maintenance
Table 61. Filter data
Panel-Type Filters
Unit Model
(AC/EC)
Qty
20 & 25 / 24 & 29 Ton
12
30/36 Ton
16
40/48 Ton
16
50, 55 / 59 Ton
20
60, 70 & 75 /
35
73, 80 & 89 Ton
90-130
25
(a) Dimensions shown for "Panel-Type Filters" apply to "Throw away", "Cleanable Wire Mesh", and "High Efficiency Throw away" Filters.
(b) S_HL units ordered with "Bag-Type Filters" or "Cartridge Filters" (box-type) include a bank of "Panel-Type Prefilters"
(c) The same "Panel-Type Prefilters" are used with "Bag-Type" and "Cartridge (box-type)" filters.
Table 62. "Wet heat" coil fin data
20, 25, 30 / 24, 29, 36 Ton
60, 70, 75 / 73, 80, 89 Ton
Note: To determine unit heating capacity (i.e. "low heat" or "high heat"), see digit 9 of the model number stamped on the unit
Table 63. Grease recommendations
Table 64. Refrigerant coil fin data
Evaporator Coil
Size
Rows/Fin
Tonnage
(ft2)
Series
20
20.3
4/168
25
20.3
4/168
30
25.5
5/168
40
32.5
5/168
50, 55
38
4/168
176
(a)
Bag-Type Filters
Size of each
Qty.
4
20 X 20 X 2
3
2
20 X 20 X 2
6
5
20 X 25 X 2
6
3
20 X 25 X 2
9
6
16 X 20 X 2
8
3
24 X 24 X 2
15
Unit Model
(AC/EC)
WC Prima Flo (hot water)
40, 50, 55 / 48, 59 Ton
WC Prima Flo (hot water)
WC Prima Flo (hot water)
40, 50 / 48, 59 Ton
90-130 Ton
nameplate.
Recommended Grease
Exxon Unirex #2
Mobil 532
Mobil SHC #220
Texaco Premium
Tube Diameter/
Surface
1/2/Enhanced
1/2/Enhanced
3/8"/Enhanced
3/8"/Enhanced
1/2/Enhanced
Cartridge Filters (box-
(b)
type)
Size of each
Qty.
12 X 24 X 19
4
24 X 24 X 19
3
12 X 24 X 19
2
24 X 24 X 19
6
12 X 24 X 19
5
24 X 24 X 19
6
12 X 24 X 19
3
24 X 24 X 19
9
12 X 24 X 19
6
24 X 24 X 19
8
12 X 24 X 19
3
24 X 24 X 19
15
Coil Type
Coil Rows
NS (steam)
NS (steam)
Recommended Operating Range
-20°F to 205°F
Aluminum Fins
Size
Rows/Fin
Tube Diameter/
(ft2)
Series
Surface
58
3/252
5/16/Enhanced
58
3/252
5/16/Enhanced
58
4/252
5/16/Enhanced
116
3/252
5/16/Enhanced
116
4/252
5/16/Enhanced
Panel-Type
(b)
Prefilters
Size of each
Qty.
Size of each
12 X 24 X 12
4
24 X 24 X 12
3
12 X 24 X 12
2
24 X 24 X 12
6
12 X 24 X 12
5
24 X 24 X 12
6
12 X 24 X 12
3
24 X 24 X 12
9
12 X 24 X 12
6
24 X 24 X 12
8
12 X 24 X 12
3
24 X 24 X 12
15
Total Coil Face
Fins per
Area (sq. ft.)
2
13.75
2
19.25
2
26.25
1
13.75 (1) 5.5 (1)
1
17.5 (2)
Condenser Coil
Copper Fins
Rows/Fin
Tube Diameter/
Series
3/156
5/16/Enhanced
3/156
5/16/Enhanced
4/156
5/16/Enhanced
3/156
5/16/Enhanced
4/156
5/16/Enhanced
(c)
12 X 24 X 2
24 X 24 X 2
12 X 24 X 2
24 X 24 X 2
12 X 24 X 2
24 X 24 X 2
12 X 24 X 2
24 X 24 X 2
12 X 24 X 2
24 X 24 X 2
20 X 24 X 2
24 X 24 X 2
Fins per
Foot
Foot
80
110
80
110
80
110
42
96
52
96
Surface
RT-SVX36G-EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents