KTM 250 XC TPI Owner's Manual page 116

Table of Contents

Advertisement

17 SERVICE WORK ON THE ENGINE
114
Main work
Pull EFI control unit
to the side.
Remove protection cap
V01689-10
Put throttle grip
V01645-11
Plug in wake-up connector
diagnostics connector
Info
The connector is included as part of the motorcycle's
separate enclosure.
Wait for at least five seconds.
Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
Wait until you can no longer hear the oil pump working.
Disconnect the wake-up connector from the diagnostics con-
nector.
V01623-10
1
upward off rubber lugs
3
of the diagnostics connector.
4
into full throttle position and secure.
5
for priming the oil pump to the
6
.
2
and hang