17 SERVICE WORK ON THE ENGINE
114
Main work
–
Pull EFI control unit
to the side.
–
Remove protection cap
V01689-10
–
Put throttle grip
V01645-11
–
Plug in wake-up connector
diagnostics connector
Info
The connector is included as part of the motorcycle's
separate enclosure.
–
Wait for at least five seconds.
–
Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
–
Wait until you can no longer hear the oil pump working.
–
Disconnect the wake-up connector from the diagnostics con-
nector.
V01623-10
1
upward off rubber lugs
3
of the diagnostics connector.
4
into full throttle position and secure.
5
for priming the oil pump to the
6
.
2
and hang