REPLACING THE LED STRIP (Optional)

TESTING THE LOOP

To make sure the installation of EK components was successful,
we recommend you perform a 24-hour leak test.
When your loop is complete and filled with coolant, connect the
pump to a PSU outside of your system. Do not connect power to
any of the other components. Turn on the PSU and let the pump
run continuously.
Inspect all parts of the loop, and in case the coolant leaks, fix
the issue and repeat the testing process. To prevent possible
damage, please ensure that all hardware is dry before the system
is powered on.
M4/M2.5 x 13.5
(LONGER) STANDOFF
STEP 1
STEP 1
If you want to replace the D-RGB LED strip, you must remove the two
(2) standoffs shown in the picture using a 6mm wrench. Remove the
stickout and replace the LED strip.
Once you have replaced the LED strip, align the holes on
the stickout with holes on the top plate, and tighten the
standoffs evenly.