MAINTENANCE

The Motorised Torque Wrench Loader is engineered for a long maintenance free life. Under normal
operation maintenance is not required.
For maintenance and recalibration of the torque instrument and transducer refer to their manuals.

Cleaning

Do not use abrasives or solvent based cleaners. Norbar recommend a propriety brand of foam based fabric /
vinyl cleaner. Use a soft cloth to avoid scratches.

Disposal

Do not dispose of this product with the general waste. To follow European Directive 2002/96/EC
on WEEE (waste electrical and electronic equipment) this product must be sent to a recycling
facility.

SPECIFICATIONS

Maximum Torque Output:
Torque Wrench Length:
Voltage Requirements:
Mains Power Fuse:
Power Consumption:
Mains Power Cable:
Ancillaries Input:
Direction Of Torque Application:
Overload (T-Box, TST, TTT or Pro-Log):
Operating Temperature Range:
Storage Temperature Range:
Sound Pressure Level:
Maximum Operating Humidity:
Weight:
Base Dimensions:
Dimensions (without extension bar)
Dimensions (with extension bar)
Environment:
NOTE:
If equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment could be impaired.
8
3000 N∙m / 2200 lbf∙ft
With small reaction plate option = 125mm to 210mm
Standard reaction arm = 220mm to 1100mm
With extension arm = up to 2200mm
Selectable 110/120 Volts AC +/- 10 %
or 220/240 Volts AC +/- 10% at 50/60 Hz.
T1A anti-surge for 220VAC.
T2A anti-surge for 110VAC.
100 W – maximum.
2.5 meters long.
3 Way 'Binder 680 Series' plug.
Clockwise and Anticlockwise.
5V DC as given by HI limit set.
0 °C to +40 °C.
-20 °C to +70 °C.
L pA does not exceed 70 dB(A).
80% Relative Humidity @30°C.
Remote Paddle Controller: 0.25 kg
Torque Wrench Loader
120 mm high x 830 mm wide x 310 mm deep.
554mm high x 1232mm wide x 382 deep
554mm high x 2442mm wide x 382 deep
Indoor use within a light industrial environment.
To environmental conditions Pollution Degree 2 & Installation
Category (Overvoltage Category) II.
40 kg