*damage to the sensor which is not used (active) does not activate an alarm 
 
 
 
 
 
 
 
 
 
 
Possible cause 
· the device has been improperly 
configured with the sensor 
· the sensor is not connected 
· mechanical damage 
the cable is too long or it has been 
·
connected improperly. 
· no contact or short circuit 
 
· CH sensor has not been installed 
properly 
· MOSFET may be damaged 
· The fan capacitor is wrong or 
damaged.  
· Too little fuel in the tank  
· Incorrect initial feeding settings and 
fan (blow) settings  
· Possible damage of the igniter 
Solution 
· check the connections on the terminal 
block 
· make sure the connection cable is not 
damaged and there is no short circuit. 
· check the insulation 
· check if the sensor works properly (by 
connecting another sensor in its place 
and checking its readings)  
· restore factory settings 
· replace the sensor 
· if the alarm continues, contact the service 
staff. 
· Check if the sensor has been installed 
properly, in the right place 
· Contact the service staff 
· Check if there is fuel in the tank 
· Check if the charging pipe is positioned at 
the right angle 
· Check if the charging pipe is not 
obstructed (by activating it in manual 
mode) 
· Check if the initial feeding settings and 
fan settings are configured properly. 
· Check the blow force in fire‐up mode 
· Check if the igniter works properly 