ENSORS
This option allows defining the type of the sensor connected:
none – no sensor connected to the input – the sensor will not be selectable in all parameters.
KTY – KTY-type temperature sensor connected to the input.
PT1000 – PT1000 temperature sensor connected to the input.
Note: If the user sets the sensor to "none" while it has been used in the operation of pumps, the pumps
operating in temperature and delta modes will be shut off and the turn-on threshold will be deactivated for
the pump working in circulation mode
P
UMP OPERATING TIME COUNTER
The function allows the user to preview the pump operating time counters to check numbers of days, hours
and minutes of operation. The controller counts the seconds of operation of individual pumps and only after
they add up to a full hour the controller stores the counter indication in the non-volatile memory. Therefore,
any shut-off, power supply failure etc. occurring before 3600 seconds are counted will cause that, when
restarted, the counter will indicate the number of full hours counted only. Pressing of pulser knob allows the
user to reset the counter.
L
ANGUAGE SELECTION
The user may select the language version of the controller menus.
I
NFORMATION
Selection of this option provides access to the information about: software version, number of times the
controller was started and the service centre telephone number. The screen is selected using the pulser.
Service centre telephone number can be edited by pressing the pulser (there are 15 fields available to be filled
with the following characters: 0-9 + - ( ) space.
A
LARMS
Each controller alarm is indicated with sound and a corresponding message displayed on the screen.
Once the fault is rectified (or the circuit is cooled) the user can exit the alarm mode by pressing any button.
The alarms supported by the system are listed below in the order of priority:
1. No sensor 1/2/3
Message displayed: „Alarm. Sensor1/2/3"
2. Temperature on the sensor 1/2/3 above alarm threshold
Message displayed:"Temperature alarm. Sensor 1/2/3"
In the case of this alarm the pumps are turned on/off according to the individual pup settings.
F
USE
The controller is equipped with WT cylindrical fuse link 3.15 A to protect the network. Fuses of higher rating
may result in controller damage.