In this way the fuel tank is calibrated and the controller will automatically inform the user about the current 
fuel level.  Such calibration is usually performed only once. When the fuel tank is filled again, it is enough to 
select the option Fuel tank full in the user's menu. 
After a fuel level panel is selected in the main screen, the display shows the estimated amount of fuel left (%) 
and the expected time needed for the fuel to be used up (days and hours). 
4.4.11
Cleaning 
* This parameter is displayed only after the grate has been activated in the service menu. 
Cleaning period 
This parameter is used to define the frequency of grate cleaning  activation. The cleaning procedure involves 
damping the CH boiler and fire‐up. If the time is set at 0, the cleaning process will be disabled. 
Grate ‐ damping 
This function is used to activate the grate after damping. The operation time may be configured in service 
menu. When the time is over, the grate relay will be disconnected.   
Grate ‐ operation mode 
This  function  is  used  to  configure  grate  operation  in  operation  mode.  The  grate  is  activated  periodically 
according to Grate ‐ pause in operation settings.  
Grate ‐ pause in operation 
This parameter defines the time left before grate activation in operation mode. It is displayed when Grate ‐ 
operation mode is active. 
4.4.12
Eco mode 
 
The user may decide if Eco mode should be active or not. Fire‐up process depends on the selected operation 
mode: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cleaning period 
Grate ‐ damping* 
Grate ‐ operation mode* 
Grate ‐ pause in operation* 
OFF 
ON 
39 