General Specifications - Renishaw VIONiC RSLM20 Installation Manual

High accuracy linear encoder system
Table of Contents

Advertisement

General specifications

Power supply
5 V −5%/+10% Typically 200 mA fully terminated
Ripple 200 mVpp maximum @ frequency up to 500 kHz
Temperature
Storage −20 °C to +70 °C
Operating 0 °C to +70 °C
Humidity
Sealing
Acceleration (system)
Operating 400 m/s², 3 axes
Shock (system)
Operating 500 m/s², 11 ms, ½ sine, 3 axes
Vibration (system)
Operating 100 m/s² max @ 55 Hz to 2000 Hz, 3 axes
Mass
Readhead 8.6 g
Cable 26 g/m
Readhead cable
Maximum readhead
cable length*
*
Extension cables available. Contact your local Renishaw representative for further details.
CAUTION: Renishaw encoder systems have been designed to the relevant EMC standards, but must
be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is
essential.
VIONiC RSLM20/RELM20 installation guide
Power from a 5 Vdc supply complying with the requirements for
SELV of standard IEC 60950‑1
95% relative humidity (non‑condensing) to IEC 60068‑2‑78
IP40
Single-shielded, outside diameter 4.25 ±0.25 mm
Flex life > 20 × 10
cycles at 30 mm bend radius
6
UL recognised component
3 m
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vionic relm20

Table of Contents