Configurations - Sensata Dimensions 24NP36 Owner's Manual

Dc to ac power inverter/charger
Table of Contents

Advertisement

Configurations

Low Batt
BCR
AC Line Qualify
CAN Instance
Baud Rate
Settings
Battery Profile
Default CV
Min CV
Max CV
Default CV Timer
Min CV Timer
Max CV Timer
Default Float V
Min Float V
Max Float V
Battery Type
LFP
LFP
(HEATED)
LFP
LFP (
)
HEATED
*The LCD converts temperature settings into a Celsius integer before transmitting to the inverter. Setting changes
of only 1°F on the LCD may not always change the setpoint within the inverter. Changes of 2°F will change the
setpoint within the inverter.
0.1C charging is the feature in which the charger will reduce the charge current to ten percent of the amp hour
rating. See the specification table for the default amp hour setting. The amp hour setting may be adjusted with CAN
or the optional LCD remote.
Page 30
Options
21.0 V
to
5 A
to
5 secs
to
1
to
250k
or
Table 8 Setting Options
Wet
1
29.2 VDC
29.0 VDC
24.0 VDC
24.0 VDC
30.8 VDC
30.6 VDC
6.0 hrs
0.5 hrs
25.0 hrs
27.2 VDC
27.0 VDC
24.0 VDC
24.0 VDC
28.4 VDC
28.6 VDC
Table 9 Battery Charger Customization Options
High Temp
Profile
Shutdown*
1
45°C/113°F
2
45°C/113°F
3
60°C/140°F
4
60°C/140°F
Table 10 LFP Setting Options
24NP Manual
Increment
24.0 V
.1 V
30 A
5 A
30 secs
5 secs
13
1
500k
N/A
Battery Type
AGM
1
28.2 VDC
24.0 VDC
29.8 VDC
6.0 hrs
6.0 hrs
0.5 hrs
0.5 hrs
25.0 hrs
25.0 hrs
27.2 VDC
24.0 VDC
28.8 VDC
Cold Temp
Shutdown*
0°C/32°F
None
0°C/32°F
None
Default
21.0 V (23.0 V for LFP)
15 A
30 secs
1
250k
Gel
LFP
1
See Table 10
28.8 VDC
27.8 VDC
29.6 VDC
0.5 hrs
0.5 hrs
25.0 hrs
27.2 VDC
26.6 VDC
27.6 VDC
Cold Reduced
Charge*
5°C/41°F
5°C/41°F
5°C/41°F
5°C/41°F

Advertisement

Table of Contents
loading

Table of Contents