Dc to ac power inverter/charger
Table of Contents

Advertisement

External Power Mode Continued
Battery Charger Continued
Battery Type
Current Limit
Phase Terminates
Phase Timeout
Accept charge voltage
@ 77°F/25°C
Accept voltage temp compensated
Maximum accept charge at low
temps
Phase Terminates
Phase Timeout
Float voltage @77°F/25°C
Float voltage temp comp
Condition voltage @77°F/25°C
Condition voltage temp
compensation
Condition duration
Condition frequency
AGM
Bulk Charge Phase
1. When battery voltage reaches the accept voltage
2. When the bulk charge timeout is reached
Bulk charge timers will extend when load management
reduces charger current below 50% (25 A)
Accept Charge Phase
28.6 VDC
30.0 VDC @ 4 °C
1. When charge current is reduced.
2. When the accept timeout is reached.
3. If the charger can't maintain the accept voltage
6 hours (may be configured through CAN or LCD)
Float Charge Phase
26.8 VDC
Condition (Equalization) Phase
N/A
N/A
N/A
N/A
Table 4 Battery Charger Recipes with BTS
24NP Manual
Gel
SEE SPEC
6 Hours
27.4 VDC
29.2 VDC
5mv/cell/°C
29.0 VDC @
30.0 VDC
-6°C
@ 10°C
26.8 VDC
26.4 VDC
5mv/cell/°C
N/A
15.5 VDC
30.24 mV/
N/A
N/A
4 hours
N/A
Control
Wet
LFP
28.8 VDC
N/A
0.5 hours
27.2 VDC
N/A
N/A
cell/°C
N/A
Manual
N/A
Page 19