Installation

7
insTallaTiOn
Warning!
Risk of injury due to improper installation.
▶ Installation may be carried out by authorised technicians only and with the appropriate tools.
Risk of injury due to unintentional activation of the system and uncontrolled restart.
▶ Secure the system against unintentional activation.
▶ Following installation, ensure a controlled restart.
7.1

Fluidic installation

Danger!
High pressure danger!
Acute risk of injury when intervening with the system.
▶ Before loosening lines and valves, turn off the pressure and vent the lines.
Check that the operating conditions comply with the performance data of the device.
7.1.1

Installation position

The installation position is arbitrary. Preferably actuator face up.
7.1.2

Prior to installation

→ Clean any dirt from the pipelines and flange connections.
→ If necessary, install a strainer upstream of the valve to protect against malfunctions.
Mesh size:
0.1 ... 0.4 mm