5
INSTALLATION
5.1 Safety instructions
DANGER!
Risk of injury from high pressure in the equipment.
▶ Before loosening the pipes and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock.
▶ Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
5.2 Before installation
Installation position:
any, actuator preferably upwards.
Procedure:
→
Check pipelines for dirt and clean.
→
Install a dirt filter before the valve inlet (≤ 0.3 mm).
WARNING!
Medium leaking through damaged connections.
▶ Do not damage sealing surfaces of the body connections during
installation.
Danger due to unsuitable screw connections.
▶ At high pressures and temperatures ensure that the thread
length (load-bearing thread turns) is adequate for each pairing of
materials.
NOTE!
Caution risk of breakage.
• Do not use the coil as a lever arm.
english
7