Bosch Rexroth AG | Electric Drives
PLC Modules MTS-P01.2 and MTS-P02.2

Addressing

and Controls
Fig.9-5:
BT bus overview
The BT bus is addressed by assigning a logical user number in the I/O editor
of the PLC programming interface. Each input image memory, as well as each
output image memory, is assigned its own address.
Each of the two image memories has a size of 128 bytes, which are available
for the connected operating devices. The number of bytes assigned in the
memory depends on the operator panel (see
the operating devices" on page
Rexroth MTA 200 | Project Planning Manual
fig. 9-6 "Memory requirements of
113).