Project Planning Manual | Rexroth MTA 200
9.5.2
Setting of the I/O Address
9.5.3
Technical Data
9.5.4
Interface Assignment
sors and actuators as well as of intelligent field devices via INTERBUS. The
INTERBUS permits bridging of distances of up to 12.8 km (from the connection
point to the last connected remote bus user), divided into segments of up to
400 m.
LK IBM2 has the following characteristics:
●
INTERBUS protocol (DIN E 19 258)
●
up to 256 bus segments
●
up to 16 user levels
●
up to 512 users per configuration
●
up to 4096 inputs and 4096 outputs per configuration (512 bytes)
●
up to 32 INTERBUS loop users per bus segment
●
CMD G4 support
The INTERBUS is configured and commissioned via the IBS CMD G4 Interbus
configurator (see DOK-CONTRL-IBS*CMD****-AW...) and the I/O editor of the
WinPCL programming interface (see DOK-CONTRL-WINPCL*6VRS-AW...).
DIP switch S1 must be set as follows (default setting) so that PCB IBM2 can
be addressed via the PC/104 bus::
1
2
3
4
OFF
OFF
ON
OFF
Fig.9-18:
Setting S1 DIP switch
Power supply
Operating voltage:
Interface data
Communication interface:
Diagnosis interface:
Operating conditions
Surrounding air temperature:
Humidity:
Air pressure:
Pin
Signal designation
1
NC
3
RxD - Receive Data
5
SGND - Ground
Electric Drives
| Bosch Rexroth AG
and Controls
PLC Modules MTS-P01.2 and MTS-P02.2
5
6
7
8
OFF
ON
OFF
OFF
+5VDC, 5% / 400 mA
2-wire remote bus, RS-422, without electrical iso‐
lation
RS-232-C
0°C - +55°C
-25°C - +70°C
max. 75% non-condensing
Pin
Signal designation
2
TxD - Transmit Data
4
NC
6
NC
119/135
Address
120
h