Remote Control

Door Control
1:normal
(LED in normal mode)
2:door permanently open
(red LED ON)
3:door permanently closed
(red LED OFF)
Sensitivity
0(min)->9(max) default=7
Microwave
Detection Mode
1:bidirectional mode
2:unidirectional mode
3:unidirectional mode with MTF
Ultraview US23-0640-09
© Copyright 2009 Besam US Inc. May not be reprinted without permission
SPECIAL NOTE: In the event you believe the frequency needs changed
for your application please contact the Besam factory.
The remote control provides ease of programming for the Ultraview. Make sure
the batteries in the remote control are charged - replace as necessary.
Open the battery compartment at the back of the remote control.
Insert 2 AAA batteries.
Re-entry Zone
1(min sensitivity)->9(max sensitivity)
Default=3
0 = off
Unlock
Check values
Lock
Automatic
Learn Time
0: 30 seconds
1: 1 minute
2: 2 minutes
3: 5 minutes
4: 10 minutes
5: 20 minutes
6: 60 minutes
9:Infinity - no learn
launch an assisted setup
restore factory settings
When restoring factory defaults(Magic
Wand+9), the sensor will self-launch a
setup, but will not change the designation
of P1 and P2