Adjusting The CUP Control Unit

Important Notice!

The 5wingmaster, when installed and set up correctly, is a safe automatic power door oper-
ator, but incorrect settings can defeat its purpose and create a safety hazard. For safety rea-
sons, never set the opening or closing speed faster than necessary to handle the traffic situa-
tion through your door. Please refer to the AN51/BHMA A156.10 - 1999 excerpt in this manual
(page 53). A correctly adjusted door is a safe door!
The start-up and adjustment must be carried out in the following order:
1. Connect the mains power.
2. Plug the PMD contact into the CUP control unit and enter your PIN code (see page 41).
Notel The PMD is not ready for use until a status or error code is displayed.
3. Select function 15 and set correct operator (see page 45).
4. Select function 27 and correct door opening direction.
5. Press button NO.4 (Auto).
6. Pressthe impulse button l. The operator carries out an open! close cycle with the factory preset values.
7. If necessary, adjust the door functions to a satisfactory performance.
Notel The door must stand still at closed position when adjustments are carried out. The
"balance
still hold the door open against the power of the spring.
8. Install activation units, accessories and EUSbattery pack if present.
9. Check that the installation complies with valid regulations and requirements of ANSI/BHMA
A156.10-1999 (reference given on pages 53-54 of this manual.)
10. Unplug the PMD, or continue with Visionpulse tuning if installed - see VP-S manual.
11. Fit the cover to the header and screw it tight to the bottom plates.
40 - AdjustmentsAndTroubleshooting
CopyTighl tOOt Beum
Automated Entrance Syttems, Inc.
o
force" should always be adjusted to the lowest possible value that will
cUP
o
- - on
FUNCTION
not be NPrirMd
May
=
VALUE
PMD
3-26-99
permiuion.
withOlJt
SwingmasterMP
US23'()186'()1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents