Ultraview Security Applications
1.There are three different configurations available with the Ultraview System:
a.Full Time 1-Way Security:
Set STD-AUX switch to AUX position - this disables the P1 sensor during the door closed position.
Set rotary switch to 2-way traffic position
Connect the normally open and common dry contacts of the secure access device
(keyswitch, card reader, prox reader, etc.) to the AUX connector of the Ultraview interface.
Performance:
1.P1 will be disabled when the door is fully closed, but will be capable to provide detection for all
other door positions.
2.P2 will always be capable to create door activation, regardless of door position.
3.Setting the rotary switch to the OFF position will disable all inputs once the door is fully closed.
b.Full Time 2-Way Security:
Set STD-AUX switch to AUX position - this disables the P1 sensor during the door closed position.
Set rotary switch to 1-way traffic position - this will disable the P2 sensor during the door closed
position. Connect the normally open and common dry contacts of the secure access device
(keyswitch, card reader, prox reader, etc.) to the AUX connector of the Ultraview interface.
Performance:
1.P1 and P2 will be disabled when the door is fully closed, but will be capable to provide detection
for all other door positions.
2.A momentary contact closure at the AUX input will always be capable to create door activation,
regardless of door position.
3.Setting the rotary switch to the OFF position will disable all inputs once the door is fully closed.
c.Part Time 1-Way Security (Day-Night Mode):
Set STD-AUX switch to STD position.
Set rotary switch to 2-way traffic position.
Connect the normally open and common dry contacts of the secure access device
(keyswitch, card reader, prox reader, etc.) as follows:
1.Connect the Normally Open contact to the AUX terminal closest to the outer edge of the interface.
2.Connect the Common contact to the #2 (Inner Impulse) terminal of the interface.
Unplug the interface from the control
Loosen terminal screw #2 (Inner Impulse)
At the backside of the interface, insert a short wire (approx.6")
Retighten terminal screw #2
Re-insert the interface into the Unislide control
Connect a second short wire to the outermost AUX terminal position as shown.
Performance:
1.P1 and P2 will operate normally while the rotary switch is in the 2-way traffic position.
There will be no secure access from either side.
Set rotary switch to 1-way traffic position -
2.The P2 sensor will be disabled during the door closed position.
3.P1 will continue to operate normally. P2 will become the secure side. Activation at the P2 side
must be initiated by a momentary closure of the secure access device.
4.Setting the rotary switch to the OFF position will disable all inputs once the door is fully closed.