7.3.2 IP configuration
Change to the entry [Basic Configuration] [2. TCP/IP]. Choose the <IPv4 Address Configu-
ration> (o) Use the following IP address. Type in these data:
Figure 7.7: Setting an IP address
Note:
When using a port on the rear side of the logger, please type in the <IP address>
192.168.0.90 and the <Default router> 192.168.0.1.
The same IP address has to be used in the data loggers configuration.
Confirm the settings with [Save].
Note:
By changing the IP address you lose the connection to the network camera.
This also will be told to you in an information window:
Figure 7.8: Hint 1
bP2-Mini_Camera_UserGuide_V2.4.1.doc
blue PiraT2 / 5E / Mini
Camera User Guide
IP address:
192.168.1.90
Subnet mask:
255.255.255.0
Default router:
192.168.1.1
Datum: 16.09.2016