P P E E R R F F O O R R M M A A N N C C E E D D A A T T A A – – N N O O Z Z Z Z L L E E S S
N N o o z z z z l l e e s s • • P P e e r r f f o o r r m m a a n n c c e e
A choice of four air discharge nozzles
(above) accommodate various heat
throw patterns illustrated on the facing
page. Equipped with adjustable louver
blades, nozzles are fabricated from
galvanized steel and are offered
either unpainted or painted to match
the finish of the blower unit heaters.
Nozzles are flanged for easy
attachment over the air discharge
opening of the blower unit heater.
40° Downward
Nozzle
40° Splitter
Nozzle
N N o o z z z z l l e e P P e e r r f f o o r r m m a a n n c c e e M M o o u u n n t t i i n n g g H H e e i i g g h h t t , , H H e e a a t t T T h h r r o o w w , , H H e e a a t t S S p p r r e e a a d d ( ( i i n n f f e e e e t t ) )
N N o o z z z z l l e e
T T y y p p e e
Max. Mounting Ht. (ft.) H
4 4 0 0 ° °
D D o o w w n n w w a a r r d d
Heat Throw (ft.) T
N N o o z z z z l l e e
Heat Spread (ft.) S
Max. Mounting Ht. (ft.) H
9 9 0 0 ° ° V V e e r r t t i i c c a a l l
N N o o z z z z l l e e
Heat Spread (ft.) S
Max. Mounting Ht. (ft.) H
4 4 0 0 ° ° S S p p l l i i t t t t e e r r
Heat Throw (ft.) T
N N o o z z z z l l e e
Heat Spread (ft.) S
Max. Mounting Ht. (ft.) H
5 5 - - W W a a y y
N N o o z z z z l l e e
Heat Spread (ft.) S
The above table is based on an inlet air temperature of 70°F and an air temperature rise of 55°F. Air deflectors on, 40° and 90° discharge nozzles set perpendicular
to the face of the air discharge opening. On 5-way nozzles all air deflectors set perpendicular to floor. Static pressure measured at 0.1" W.C. for 90° nozzle, 0.2" W.C.
for 40° downward and 5-way nozzle, and 0.3" W.C. for 40° splitter nozzle. Outlet velocities are approximately 1750 FPM for the 40° nozzles, 1000 FPM for the 90°
nozzle and 1300 FPM for 5-way. For motor size, drive and blower rpm refer to pages 18 and 19. Mounting height measured from bottom of unit.
2 2 2 2
T
S
T
T
S
B B V V 5 5 0 0
B B V V 7 7 5 5
B B V V 1 1 0 0 0 0 B B V V 1 1 2 2 5 5 B B V V 1 1 4 4 5 5 B B V V 1 1 7 7 5 5 B B V V 2 2 0 0 0 0
14
16
41
49
14
16
15
17
15
17
12
14
17
20
H
H
S
M M o o d d e e l l N N u u m m b b e e r r
18
22
21
24
54
66
63
72
18
22
21
24
18
22
22
21
18
22
22
21
16
20
20
21
41
50
49
52
81
100
97
104
15
18
17
18
21
26
24
25
90° Vertical
Nozzle
H
S
S
5-Way
Nozzle
S
B B V V 2 2 5 5 0 0 B B V V 3 3 0 0 0 0
27
26
28
81
78
83
27
26
28
24
26
28
24
26
28
24
23
26
59
58
65
117
116
129
20
21
20
28
30
27
B B V V 3 3 5 5 0 0 B B V V 4 4 0 0 0 0
32
32
96
96
32
32
32
32
32
32
30
32
75
80
151
160
23
26
32
37