Chapter 6 Installation Procedure; Cathodic Protection; Mechanical Components Assembly - Emerson Daniel Series User Manual

Liquid turbine meter
Hide thumbs Also See for Daniel Series:
Table of Contents

Advertisement

User manual
P/N 3-9008-507
6
Installation procedure
6.1

Cathodic protection

Table 6-1: Standards for cathodic protection
Material
Carbon steel
(1)
Consult the factory for other protection.
6.2

Mechanical components assembly

Install the meter housing (e.g., flanges) onto the pipeline.
The meter housing internal components are assembled by the factory. The components
do not need to be uninstalled or reinstalled unless maintenance is required.
6.2.1
Fasteners
Property class of the fastener is in accordance with ASME B16.5.
Stud bolt and nut types
All fasteners (nuts and studs) used in assembling Daniel turbine meters are made of one of
the materials listed in the table below.
Table 6-2: Bolt material selection
Bolt material selection
ASTM SA 193 Grade B7 <63.5 mm (<2.5 in.)
ASTM SA 193 Grade B7M <63.5 mm (<2.5 in.)
ASTM SA 320 Grade L7 <63.5 mm (<2.5 in.)
ASTM SA 320 Grade L7M <63.5 mm (<2.5 in.)
ASTM SA 449 <25.4 mm (<1.0 in.)
ASTM SA 453 Grade 660
Selection of flange stud bolts and nuts
Select all fasteners (nuts and studs) used in a hydrostatic test according to the flange
size and quantity listed in ASME ANSI B16.5.
Use the shortest stud bolt that permits full engagement of the thread through the nut
by hand-tightening.
Use only clean, rust-free nuts and stud bolts.
User manual
Daniel standard cathodic protection
Zinc Phosphate
Description
High strength low alloy steel
Controlled strength low alloy steel
High strength low alloy low temperature steel
Controlled hardness low temperature steel
Quenched and tempered steel
High temperature stainless steel
Installation procedure
September 2020
(1)
65