5-3. VIDEO SECTION ADJUSTMENT
NTSC model: DCR-IP5/IP7BT
PAL model : DCR-IP5E/IP7E
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1.
Equipment to Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• Tracking adjustment (XH8-1)
Parts code: 8-967-998-01
• Operation check for NTSC (XH8-2)
Parts code: 8-967-998-11
• Operation check for PAL (XH8-3)
Parts code: 8-967-998-21
12) Adjustment remote commander (J-6082-053-B)
13) Multi-cable for service (J-6082-535-A)
5-39
DCR-IP5/IP5E/IP7BT/IP7E