SERVICE MODE

1. Setting the Test Mode

Page D
Data
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
05
Forced memory power ON
• Before setting the data, select page: 0, address: 01, and set data:
01.
• For page D and F, the data set is recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander. And select page: 0, address: 01, and set data:
00.

2. Emergence Memory Address

Page C
Address
20
EMG code when first error occurs
Upper: MSW code when shift starts when first
22
error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
23
occurs
24
EMG code when second error occurs
Upper: MSW code when shift starts when second
26
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
27
occurs
28
EMG code when last error occurs
Upper: MSW code when shift starts when last error
2A
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
2B
occurs
When no error occurs in this unit, data "00" is written in the above
addresses (20 to 2B). When first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(20 to 23). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(24 to 27).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (28 to 2B).
Note: After completing adjustments, be sure to initialize the data of
addresses 20 to 2B to "00".
Address 10
Function
Address 20 to 2B
Contents
Initializing method:
Order Page Address Data
1
0
01
2
3
F6
3
3
F6
4
0
01

2-1. EMG Code (Emergency Code)

Codes corresponding to the errors which occur are written in
addresses 20, 24 and 28. The type of error indicated by the code are
shown in the following table.
Code
00
No error
10
Loading motor emergency during loading
11
Loading motor emergency during unloading
20
T reel emergency during unloading
21
S reel emergency during unloading
22
T reel emergency during normal rotation
23
S reel emergency during normal rotation
31
FG emergency of the capstan
32
Emergency during reverse rotation of the capstan
40
FG emergency at the start up of the drum
41
PG emergency at the start up of the drum
42
FG emergency during normal rotation of the drum
43
PG emergency during normal rotation of the drum
5-56
Procedure
01
Set the data.
01
Set the data and press PAUSE
button.
Check that the data changes to
"00".
00
Set the data.
Emergency Type