1-1-2.

Preparations

Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-3.
2)
Connect the adjustment remote commander to A/V jack via
the multi-cable for service (J-6082-535- A).
Note 3: As Removing the JK-209 board (removing the VC-263 board
CN2024) means removing the lithium 3V power supply (FK1900
block BT001), data such as date, time, user-set menus will be lost.
After completing adjustments, reset these data. If the CN2024 has
been removed, the self-diagnosis data and data on history of use
(total drum rotation time etc. ) will be lost. Before removing, note
down the self-diagnosis data (data of page: 2, address: B0 to C6)
and the data on history use (data of page: 2, address: A2 to AA).
(Refer to "5-4. Service Mode" for the self-diagnosis data and data
on the history use.)
Note 4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the Control switch block (FK1900) removed. After
completing adjustments, be sure to exit the "Forced Camera Power
ON Mode".
Note 5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Pattern box
Front of the lens
5-5
DCR-IP5/IP5E/IP7BT/IP7E
1.5 m
Fig. 5-1-2.