middle of the first deviating mirror. The height of the laser pointer
and the height where the pointer hits have to be identical.
Repeat the procedure and align the laser pointer at the bottom
part of the unit. Repeat these steps several times, if necessary.
Align the first deviation mirror so that the laser beam hits the
second deviating mirror in the position described before.
Turn the mounting brackets to set the angle, an when the
required position is reached, tighten the screws. Use the slot
holes at the deviating mirror and/or adapt the inclination of the
floor bracket by adding adjusting washers.
Align the second deviating mirror in the same way and make sure
that the laser hits the receiver unit.
Insert the laser pointer in the upper part of the receiver unit and
align it so that the laser beam reflected by the deviating mirrors
hits the transmitter unit.
Repeat the same process with the laser pointer in the lower part
of the receiver unit.
Fig. 2
Screw M6x50
PSEN op Mirror Bracket Kit/1
Original document