Function of terminals and jumpers
Terminal board A
Network
Terminal board B
+B
Input 12 V DC 350 mA
5
Earth
21
Output 11 V DC
8
Common call output 1
8A
Common call output 2
11
Audio from entry panel
12
Audio to entry panel
23
Output 14 V AC
16
+
NO
Normally open
C
Common
NC
Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal board C
5
Earth
8
Audio to internal receiver
9
Audio to internal receiver
relay contacts
Technical data
Type
Power supply 50-60 Hz (V AC)
Power consumption (VA)
Output voltages at 11 V DC (mA)
Output voltages at 14 V AC (mA)
Peak output voltages (mA)
Operating output voltages (mA)
Storage temperature (°C)
Operating temperature (°C)
IP Rating
Installation
The device can be installed on DIN rails (EN 50022) on a suit-
able switchboard, or on the wall using the terminal covers.
☞ 
Ensure that the power supply cables are appropriately fi xed
in place, to avoid stresses, traction or twisting.
To dismantle the device, proceed as shown in fi gure 2-3.
See fi gure 1 for dimensions.
The power supply must always be installed horizontally.
Ensure there is correct ventilation if the power supply is
installed in a metal case.
A/200R
230
34
150
650
300
650 (1A)
-25 to +70
0 to +35
IP30