General Information; Rates And Effi Ciencies - Continental Fireplaces Builder Series Installation Manual

Hide thumbs Also See for Builder Series:
Table of Contents

Advertisement

Available languages

Available languages

Installer: please fi ll out appliance
checklist in the Owner's manual.

1.0 general information

When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
f i r e - p a r t s . c o m
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and effi ciencies
Fuel Type
Altitude (FT)
Max. Input (BTU/hr)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Confi ctions)
*Max. inlet pressure not to exceed 13" w.c. (32mb).
standard checklist
Natural Gas
0-4,500
26,000
4.5" w.c. (11mb)
7" w.c. (17mb)*
3.5" w.c. (9mb)
Propane
0-4,500
25,000
11" w.c. (27mb)
13" w.c. (32mb)
10" w.c. (25mb)
W415-1850 / A / 03.06.19
EN
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx36ntr-1Cx36ntre-1Cx36ptr-1Cx36ptre-1

Table of Contents