Typical Vent Installation - Continental Fireplaces Builder Series Installation Manual

Hide thumbs Also See for Builder Series:
Table of Contents

Advertisement

Available languages

Available languages

A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings
and serves both dwellings. Local codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼" (31.8mm) air gap
all around between the inner liner and outer liner is required for safe operation.
This appliance is certifi ed for use with a power vent kit. Contact your local authorized dealer for more information.
If approved for use with a power vent kit, state: "This appliance is certifi ed for use with a
power vent kit. Contact your local authorized dealer for more information."
If not, cover with a white box.
** When a vertical rise is used as part of the venting confi guration, a 0" (0mm) rise per foot is acceptable.
f i r e - p a r t s . c o m
2.1

typical vent installation

8" (203mm)
minimum
* See "venting" section
CX36-1 REQUIRED RISE ON HORIZONTAL
VENTING
Rear Vent
1" (25mm) / FT**
1" (25mm) / FT**
Top Vent
0" / FT
0" / FT
Rear Vent
6" (152mm)
Corner
6" (152mm)
24" (61cm)
maximum
42 5/8"
(108cm)
minimum plus
rise*
TOP VENT
venting requirements
16" (40.6cm)
minimum
40ft (12m)
Maximum
3ft (1m)
minimum
34 5/8"
(86cm)
W415-1850 / A / 03.06.19
EN
11