INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50, FOR VENTED GAS FIREPLACES.
FOR INDOOR USE ONLY
SAFETY INFORMATION
WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
B36NTR / B36NTRE &
GX36NTR-1 / GX36NTRE-1
NATURAL GAS MODEL
B36PTR / B36PTRE &
GX36PTR-1 / GX36PTRE-1
PROPANE GAS MODEL
DANGER
!
HOT GLASS WILL CAUSE
DO NOT TOUCH GLASS UNTIL
NEVER ALLOW CHILDREN TO
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
AVERTISSEMENT
!
LA VITRE CHAUDE CAUSERA
NE PAS TOUCHER LA VITRE
AVANT QU'ELLE AIT REFROIDI.
ENFANTS TOUCHER LA VITRE.
BURNS.
COOLED.
TOUCH GLASS.
DES BRÛLURES.
1.28G
W415-1678 / B / 03.27.17
NE JAMAIS LAISSER LES
EN
FR
PG
83

Advertisement

Table of Contents
loading

Summary of Contents for Continental Fireplaces B36NTR

  • Page 1 NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50, FOR VENTED GAS FIREPLACES. B36NTR / B36NTRE & GX36NTR-1 / GX36NTRE-1 FOR INDOOR USE ONLY NATURAL GAS MODEL SAFETY INFORMATION B36PTR / B36PTRE &...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS NOTE: The camera icon indicates video tutorials are available as additional reference, visit http://mynapoleon.napoleonproducts.com/download/index/44/1 INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATION SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION 3.3.2 CORNER TERMINATION...
  • Page 3: Installation Overview

    13.0 B36 ACCESSORIES 14.0 GX36-1 ACCESSORIES GX36-1 ACCESSORIES (PAGE 2) 15.0 TROUBLESHOOTING (ELECTRONIC) 16.0 TROUBLESHOOTING (MILLIVOLT) 17.0 WARRANTY 18.0 SERVICE HISTORY NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. 1.0 INSTALLATION OVERVIEW See the section “VENTING” See the section “MINIMUM and “INSTALLATION”.
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND ARE PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS 15 3/8" 391mm 4" 102mm 7" 178mm 34 5/8" 9 1/16" SAFETY BARRIER 230mm 879mm 8" 24" 203mm 610mm 35" 889mm 2 3/16" 15 3/4" GAS INLET 55.5mm 400mm W415-1678 / B / 03.27.17...
  • Page 6: General Instructions

    GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48 INCHES (121.9cm) FROM THE FRONT FACE OF THE APPLIANCE.
  • Page 7: General Information

    13" (32mb) w.c. Pressure Manifold Pressure (Under 3.5" (9mb) w.c. 10" (25mb) w.c. 3.5" (9mb) w.c. 10" (25mb) w.c. Flow Conditions) MODEL DESIGNATIONS FUEL TYPE OPERATING SYSTEM B36NTR NATURAL MILLIVOLT B36NTRE NATURAL ELECTRONIC IGNITION B36PTR PROPANE MILLIVOLT B36PTRE PROPANE ELECTRONIC IGNITION...
  • Page 8: Rating Plate Information

    DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR UNE UTILISER AVEC BARRIÈRE W565-0144. SUIVEZ LES INSTRUCTIONS 9700539 (WSL) 4001657 (NGZ) D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION 4001658 (NAC) 4001659 (WUSA) B36NTR CB36NTR MODEL CB36PTR B36PTR B36NTRE CB36NTRE CB36PTRE...
  • Page 9: Venting

    3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT (0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 10: Venting Lengths And Components

    VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles and air terminal locations as set out in this manual apply to all vent systems and must be adhered to.
  • Page 11: Typical Vent Installation

    TYPICAL VENT INSTALLATION 16" (40.6cm) MINIMUM 40 FT (12.2M) MAXIMUM 24" (61cm) 3 FT (1M) MAXIMUM MINIMUM 8" (20.3cm) MINIMUM 42 5/8" (1.08m) MINIMUM PLUS RISE* 34.8" 34.8" (88.4cm) (88.4cm) TOP VENT W415-1678 / B / 03.27.17...
  • Page 12 16" (40.6cm) MINIMUM 40 FT (12.2M) MAXIMUM 3 FT (1M) MINIMUM 20" (50.8cm) 24" (61cm) 24" MINIMUM (61cm) PLUS RISE* REAR VENT * SEE "VENTING" SECTION W415-1678 / B / 03.27.17...
  • Page 13: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (30.5cm) above grade. The maximum allowable vent length is 10’...
  • Page 14: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet ≤ 15 feet = 2 x ACTUAL (0.9m) (4.6m) INSTALLATIONS CANADA U.S.A. 12” (30.5cm) 12” (30.5cm) Clearance above grade, veranda porch, deck or balcony. 12” (30.5cm) 9” (229mm) Clearance to windows or doors that open.
  • Page 15: Venting Application Flow Chart

    VENTING APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 16: Definitions

    DEFINITIONS For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 90°*) in feet - combined vertical vent lengths in feet...
  • Page 17: Top Exit Horizontal Termination

    TOP EXIT HORIZONTAL TERMINATION ) < (V Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H 40 (12.2) 40 (12.2) 39 (11.9) 39 (11.9) REQUIRED 30 (9.1) REQUIRED 30 (9.1) VERTICAL...
  • Page 18 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) 150 (381) 147 (373) REQUIRED VERTICAL 100 (254) RISE IN INCHES (CENTIMETERS) V 57 (145) 50 (127) 8 (20.3) 20 (6.1)
  • Page 19: Rear Exit Horizontal Termination

    REAR EXIT HORIZONTAL TERMINATION ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 40 (12.2) 38.3 (11.7) REQUIRED 30 (9.1) VERTICAL RISE IN 20 (6.1) FEET (METERS) V 10 (3.1)
  • Page 20 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H 150(3810) 12.5 (3.8) 147 (3733.8 12.25 (3.7) REQUIRED VERTICAL RISE IN 100 (2540) 8.3 (2.54) FEET (METERS)V (1.68)
  • Page 21: Top And Rear Exit Vertical Termination

    3.10 TOP AND REAR EXIT VERTICAL TERMINATION ) < (V See graph to determine the required vertical rise V Simple venting configurations. for the required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1) 3 (0.9) (1.5)
  • Page 22 ) > (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL 10 (3.1) RISE IN FEET 3 (0.9) (METERS)V (1.5) (3.1) (4.6) (6.1) (7.6) (9.1) HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS)H The shaded area within the lines represents acceptable...
  • Page 23: Rear Exit

    3.11 REAR EXIT WARNING FAILURE TO CREATE A SEAL TO THE FIREBOX WITH THE EXHAUST COLLAR ASSEMBLY WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE. Remove the safety screen and glass front, refer to " SAFETY SCREEN / DOOR REMOVAL AND INSTALLATION"...
  • Page 24: Top Exit

    3.13 TOP EXIT WARNING FAILURE TO CREATE A SEAL TO THE FIREBOX WITH THE EXHAUST COLLAR ASSEMBLY WILL CAUSE THE APPLIANCE TO FUNCTION IMPROPERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE. NOTE: This appliance has been factory shipped as a rear vent. Remove the safety screen and glass door, refer to "...
  • Page 25: Installation

    4.0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY. IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE, ENSURE THE REMOTE RECEIVER IS IN THE “OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.
  • Page 26: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 27: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 28: Vertical Air Terminal Installation

    4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” (51mm) SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. NOTE : Fastening hardware provided with appropriate roof terminal and liner kits. Fasten the roof support to the roof using 6 screws. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 29: Appliance Vent Connection

    4.2.3 APPLIANCE VENT CONNECTION Install the inner exhaust fl ue collar to the appliance. Secure #8 X 1/2” with a minimum of 3 #8 screws. Seal the joint and screw SELF holes using Mill Pac sealant (W573-0007) (not supplied). DRILLING Install the outer fl ex pipe to the appliance.
  • Page 30: Vertical Air Terminal Installation

    4.3.2 VERTICAL AIR TERMINAL INSTALLATION Move the appliance into position. INNER PIPE Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 31: Restricting Vertical Vents

    4.3.3 RESTRICTING VERTICAL VENTS WARNING TURN OFF GAS AND ELECTRICAL SUPPLY BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE IS COOL. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTION EXACTLY. TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND CHILDREN.
  • Page 32: Vertical Through Existing Chimney

    4.4 VERTICAL THROUGH EXISTING CHIMNEY WARNING RISK OF FIRE! CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON-COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD RESULT IN A FIRE. This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum fl ex vent system running the full length of a masonry chimney.
  • Page 33: Mobile Home Installation

    MOBILE HOME INSTALLATION This appliance must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate.
  • Page 34: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 35: Framing

    5.0 FRAMING B36 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 36: B36 Minimum Framing Dimensions

    5.1.1 B36 MINIMUM FRAMING DIMENSIONS 35" 88.9cm 16" 40.6cm FRENCH W415-1678 / B / 03.27.17...
  • Page 37 Minimum clearance to combustible construction from appliance and vent surfaces: Combustible Framing: 0" to stand-offs 1" (25mm) to bottom and sides of the vent pipe* 3" (76.2mm) to top of the vent pipe* Combustible Finishing: 0" to rear stand offs 0"...
  • Page 38: Minimum Enclosure Clearances

    MINIMUM ENCLOSURE CLEARANCES B36 TOP VENT TOP EXIT ENCLOSURE The appliance requires a minimum enclosure height of 50 1/2" (1.28m). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
  • Page 39 B36 MINIMUM REAR VENT CLEARANCES For rear vent termination not exceeding 10" (254mm) of horizontal vent run. NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. REAR EXIT ENCLOSURE The appliance requires a minimum non-combustible enclosure height of 41"...
  • Page 40 B36 MAXIMUM REAR VENT CLEARANCES (EXAMPLE 1) NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (1.04m). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 41 B36 MAXIMUM REAR VENT CLEARANCES (EXAMPLE 2) NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41" (1.04m). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 42: Gx36-1 Framing

    GX36-1 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 43: Gx36-1 Minimum Framing Dimensions

    5.3.1 GX36-1 MINIMUM FRAMING DIMENSIONS 35" 88.9cm 16" 40.6cm FRENC W415-1678 / B / 03.27.17...
  • Page 44 Minimum clearance to combustible construction from appliance and vent surfaces: Combustible Framing: 0" to stand-offs 1" (25mm) to bottom and sides of the vent pipe* 3" (76.2mm) to top of the vent pipe* Combustible Finishing: 0" to rear stand offs 0"...
  • Page 45: Minimum Enclosure Clearances Gx36-1

    MINIMUM ENCLOSURE CLEARANCES GX36-1 GX36-1 TOP VENT NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. * See "MINIMUM FRAMING DIMENSION" section for details on reducing vent pipe top clearances. These parameters also apply to the illustrations found in the "MINIMUM ENCLOSURE CLEARANCES"...
  • Page 46 GX36-1 MINIMUM REAR VENT CLEARANCES For rear vent termination not exceeding 10" (254mm) of horizontal vent run. NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 44"...
  • Page 47 GX36-1 MAXIMUM REAR VENT CLEARANCES (EXAMPLE 1) NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 44" (1.11m). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 48 GX36-1 MAXIMUM REAR VENT CLEARANCES (EXAMPLE 2) NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration. REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 44" (1.11m). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 49: Non-Combustible Facing Material

    NON-COMBUSTIBLE FACING MATERIAL WARNING: Non-combustible facing material must not project more than 4” (101.6mm) from the face of the door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2” (50.8mm) for every additional 1” (25mm) of projection. If using an optional surround, the same rule applies, starting from the top of the surround.
  • Page 50: Recessed Installation

    RECESSED INSTALLATION WARNING INSTALLING A TELEVISION OR OTHER ELECTRONICS ABOVE THE APPLIANCE MAY CAUSE DISCOLOURATION, MELTING OR DAMAGE TO THE ELECTRONICS. USE CLEARANCES AS GUIDELINES AND REFER TO YOUR MANUFACTURER’S INSTRUCTIONS FOR FURTHER INFORMATION. CLEARANCES CHART 6" (152.4mm) MAX 10" (254mm) MIN 44"...
  • Page 51: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 52: Finishing

    6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. IF FINISHING THE FRONT OF THE APPLIANCE, IT MUST BE FINISHED WITH ANY NON- COMBUSTIBLE MATERIAL SUCH AS BRICK, MARBLE, GRANITE, ETC. DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS REMOVED, CRACKED, BROKEN OR SCRATCHED.
  • Page 53: Front Hood Installation

    Leave a hand on the glass door during entire door removal. The glass door is secured to the firebox with two spring latches along the top and two along the bottom. Pull the handles of the latches forward, then lift the latches out from the door frame to release the top of the door.
  • Page 54: B36 Log Placement

    B36 LOG PLACEMENT WARNING FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR.
  • Page 55: Gx36-1 Log Placement

    GX36-1 LOG PLACEMENT WARNING FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR.
  • Page 56: Charcoal Embers

    CHARCOAL EMBERS WARNING CHARCOAL EMBERS, VERMICULITE AND CHARCOAL LUMPS ARE NOT TO BE PLACED ON THE BURNER. Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used. NOTE: Charcoal embers are not to be placed on the burner.
  • Page 57: Wiring Diagram

    7.0 WIRING DIAGRAM B36 ELECTRONIC WIRING DIAGRAM WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH This appliance comes equipped with a battery back-up. If this back-up is used, install 4AA batteries (not supplied) into the holder and connect to the wire harness. ACS/IPI SWITCH (OPTIONAL)
  • Page 58: Gx36-1 Electronic Wiring Diagram

    GX36-1 ELECTRONIC WIRING DIAGRAM WARNING DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT. RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH.
  • Page 59 WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH. W415-1678 / B / 03.27.17...
  • Page 60: Operation (Electronic)

    8.0 OPERATION (ELECTRONIC) B36NTRE/GX36NTRE-1 & B36PTRE/GX36PTRE-1 WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 61: Operation (Millivolt)

    9.0 OPERATION (MILLIVOLT) B36NTR/GX36NTR-1 & B36PTR/GX36PTR-1 WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 62: Adjustment

    10.0 ADJUSTMENT 10.1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
  • Page 63: Flame Characteristics

    10.3 FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ame 3/8” - 1/2” appears abnormal call a service person. (9.5mm - 12.7mm) FLAME MUST ENVELOP UPPER 3/8"...
  • Page 64: Maintenance

    11.0 MAINTENANCE MAINTENANCE WARNING MAINTENANCE MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. DO NOT PAINT THE PILOT ASSEMBLY. This appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person.
  • Page 65: Annual Maintenance

    11.1 ANNUAL MAINTENANCE WARNING THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE. NEVER VACUUM HOT EMBERS. DO NOT PAINT THE PILOT ASSEMBLY. • This appliance will require maintenance which should be planned on an annual basis. •...
  • Page 66: Care Of Glass

    11.3 CARE OF GLASS DO NOT CLEAN GLASS WHEN HOT! DO NOT USE WARNING ABRASIVE CLEANERS TO CLEAN GLASS. HOT GLASS WILL Buff lightly with a clean dry soft cloth. Clean both sides CAUSE BURNS. of the glass after the fi rst 10 hours of operation with a DO NOT TOUCH GLASS recommended fi replace glass cleaner.
  • Page 67: B36 Overview

    W415-1678 / B / 03.27.17...
  • Page 68: B36 Millivolt Valve Assembly

    W415-1678 / B / 03.27.17...
  • Page 69: B36 Electronic Valve Assembly

    W415-1678 / B / 03.27.17...
  • Page 70: Gx36-1 Overview

    W415-1678 / B / 03.27.17...
  • Page 71: Gx36-1 Millivolt Valve Assembly

    W415-1678 / B / 03.27.17...
  • Page 72: Gx36-1 Electronic Valve Assembly

    W415-1678 / B / 03.27.17...
  • Page 73: B36 Accessories

    W415-1678 / B / 03.27.17...
  • Page 74: Gx36-1 Accessories

    W415-1678 / B / 03.27.17...
  • Page 75: Gx36-1 Accessories (Page 2)

    W415-1678 / B / 03.27.17...
  • Page 76: Troubleshooting (Electronic) 76 En

    15.0 TROUBLESHOOTING (ELECTRONIC) WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 77 SYMPTOM PROBLEM TEST SOLUTION Continues to spark Short or loose Verify all connections. Verify the connections from the and pilot lights, but connection in sensor rod. pilot assembly are tight; also verify these connections are main burner will not not grounding out to any metal. light.
  • Page 78: Troubleshooting (Millivolt)

    16.0 TROUBLESHOOTING (MILLIVOLT) WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 79 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. Check if the push button igniter needs tightening. PILOT BURNER Replace the wire if the wire insulation is broken or frayed.
  • Page 80: Warranty

    17.0 WARRANTY NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 81: Service History

    18.0 SERVICE HISTORY 43.1 W415-1678 / B / 03.27.17...
  • Page 82 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gas Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 7200 Trans Canada Highway, Montreal, Quebec, Canada H4T 1A3 Fireplaces / Heating &...
  • Page 83 NE LAISSEZ PAS LES ENFANTS OU AUTRES INDIVIDUS À RISQUE SEULS À PROXIMITÉ DE L’APPAREIL. INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION CERTIFIE CANADIENNES ET AMÉRICAINES: CSA 2.22 ET ANSI Z21.50, POUR LES FOYER À GAZ VENTILÉ. B36NTR / B36NTRE & GX36NTR-1 / GX36NTRE-1 POUR USAGE INTÉRIEUR SEULEMENT MODÈLE GAZ NATUREL CONSIGNES DE SÉCURITÉ...
  • Page 84 TABLE DES MATIÈRES NOTE: L'icône du camera indique que les vidéos sont disponibles comme une référence supplémentaire, visitez http://mynapoleon.napoleonproducts.com/download/index/44/1 VUE D'ENSEMBLE DE L'INSTALLATION INTRODUCTION DIMENSIONS INSTRUCTIONS GÉNÉRALES INFORMATIONS GÉNÉRALES INFORMATION DE LA PLAQUE D’HOMOLOGATION ÉVACUATION LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS INSTALLATIONS TYPIQUES D'ÉVENTS INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1...
  • Page 85: Vue D'ensemble De L'installation

    13.0 B36 ACCESSORIES 14.0 GX36-1 ACCESSORIES GX36-1 ACCESSORIES (PAGE 2) 15.0 GUIDE DE DÉPANNAGE (ÉLECTRONIQUE) 16.0 GUIDE DE DÉPANNAGE (MILLIVOLT) 17.0 GARANTIE NOTE : Les modifications, autres qu’éditoriales, sont indiquées par une ligne verticale dans la marge. 1.0 VUE D'ENSEMBLE DE L'INSTALLATION Voir la section Voir les sections «...
  • Page 86: Introduction

    2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET SONT INTERDIT. AVERTISSEMENT • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 87: Dimensions

    DIMENSIONS 15 3/8" 391mm 4" 102mm 7" 178mm 34 5/8" 9 1/16" SAFETY BARRIER ÉCRAN DE PROTECTION 230mm 879mm 8" 24" 203mm 610mm 35" 889mm 2 3/16" 15 3/4" ENTRÉE GAS INLET 55.5mm DU GAZ 400mm W415-1678 / B / 03.27.17...
  • Page 88: Instructions Générales

    INSTRUCTIONS GÉNÉRALES AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. PRÉVOYEZ UN ACCÈS SUFFISANT POUR ENTRETENIR ET OPÉRER L’APPAREIL. ASSUREZ-VOUS D'UNE QUANTITÉ SUFFISANTE D’AIR DE VENTILATION. N’OBSTRUEZ JAMAIS L’OUVERTURE DE L’APPAREIL.
  • Page 89: Informations Générales

    Pression au collecteur 3.5" (9mb) w.c. 10" (25mb) w.c. 3.5" (9mb) w.c. 10" (25mb) w.c. (lorsque le gaz circule) DESIGNATIONS DU MODÈLE SYSTÈME DE TYPE DE CARBURANT FONCTIONNEMENT B36NTR NATUREL MILLIVOLT B36NTRE NATUREL ALLUMAGE ÉLECTRONIQUE B36PTR PROPANE MILLIVOLT B36PTRE PROPANE ALLUMAGE ÉLECTRONIQUE...
  • Page 90: Information De La Plaque D'homologation

    DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR UNE UTILISER AVEC BARRIÈRE W565-0144. SUIVEZ LES INSTRUCTIONS 9700539 (WSL) 4001657 (NGZ) D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION 4001658 (NAC) 4001659 (WUSA) B36NTR CB36NTR MODEL CB36PTR B36PTR B36NTRE CB36NTRE CB36PTRE...
  • Page 91: Évacuation

    3.0 ÉVACUATION AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’ÉVENT ET À L’APPAREIL. SI LE SYSTÈME D’ÉVENT EST FOURNI AVEC DES ESPACEURS, LES COURSES HORIZONTALES ET VERTICALES DU SYSTÈME DOIVENT ÊTRE SUPPORTÉES À TOUS LES 3 PI (0,9m). UTILISEZ DES SUPPORTS OU DES ATTACHES INCOMBUSTIBLES ÉQUIVALENTS AFIN DE MAINTENIR LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES.
  • Page 92: Longueurs Des Conduits D'évacuation Et Composants

    LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent ou Metal-Fab. Les minimums et maximums des longueurs d’évent, pour les installations verticales et horizontales, et les emplacements des terminaisons pour les deux systèmes sont précisés dans ce manuel et doivent être respectés.
  • Page 93: Installations Typiques D'évents

    INSTALLATIONS TYPIQUES D'ÉVENTS 16" (40,6cm) MINIMUM 40 PI (12,2M) MAXIMUM 24" (61cm) 3 PI (1M) MAXIMUM MINIMUM 8" (20,3cm) MINIMUM 42 5/8" (1,11M) MINIMUM PLUS LA PENTE* 34.8" 34.8" (88,4cm) (88,4cm) ÉVACUATION SUR LE DESSUS W415-1678 / B / 03.27.17...
  • Page 94 16" (40,6cm) MINIMUM 40 PI (12,2M) MAXIMUM 3 PI (1M) MINIMUM 20" (50,8cm) 24" (61cm) 24" MINIMUM PLUS (61cm) LA PENTE * ÉVACUATION SUR L’ARRIÈRE * VOIR LA SECTION « ÉVACUATION » W415-1678 / B / 03.27.17...
  • Page 95: Installations Particulières D'évents

    INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1 ENSEMBLE PÉRISCOPIQUE Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces (30,5cm) au-dessus du niveau du sol.
  • Page 96: Emplacements Et Dégagements Minimaux De La Terminaison

    EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON COVERED BALCONY APPLICATIONS ††* = 3 feet ≤ 15 feet = 2 x ACTUAL (4.6m) (0.9m) INSTALLATIONS CANADA U.S.A. 12” (30.5cm) 12” (30.5cm) Clearance above grade, veranda porch, deck or balcony. 12” (30.5cm) 9”...
  • Page 97: Charte D'application Des Évacuations

    CHARTE D'APPLICATION DES ÉVACUATIONS ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale La course verticale est La course verticale est plus grande ou égale à est plus petite que la plus grande ou égale à est plus petite que la course horizontale.
  • Page 98: Légende

    LÉGENDE Les symboles suivants sont utilisés dans le calcul et les exemples d’évacuation : > - plus grand que > - plus grand ou égal à < - plus petit que < - plus petit ou égal à - total de la longueur des courses horizontales (Hr) et des déviations (Ho) en pieds - longueur des courses horizontales combinées en pieds - facteur de la valeur d’une déviation : 0,03 (du total des degrés de déviation - 90°*) en pieds - longueur des courses verticales combinées en pieds...
  • Page 99: Évacuation Sur Le Dessus Terminaison Horizontale

    ÉVACUATION SUR LE DESSUS TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple (un coude de 90° Consultez le graphique pour déterminer la course verticale seulement). nécessaire V par rapport à la course horizontale requise H 40 (12,2) 39 (11,9) COURSE 30 (9,1) VERTICALE REQUISE EN...
  • Page 100 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H (un coude de 90° seulement) 150 (381) 147 (373) COURSE VERTICALE 100 (254) REQUISE EN POUCES (CENTIMÈTRES)V 57 (145) 50 (127)
  • Page 101: Évacuation Sur L'arriére Terminaison Horizontale

    ÉVACUATION SUR L'ARRIÉRE TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire (deux coudes de 90° seulement) par rapport à la course horizontale requise H 40 (12,2) 38,3 (11,7) COURSE 30 (9,1) VERTICALE REQUISE EN PIEDS...
  • Page 102 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (deux coudes de 90° seulement) nécessaire V par rapport à la course horizontale requise H 12,5 (3,8) 12,25 (3,7) COURSE VERTICALE 8,3 (2,54) REQUISE EN PIEDS (MÈTRES) V (1,68) 4,2 (1,3)
  • Page 103: Évacuation Sur L'arriére Et Au Dessus Terminaison Verticale

    3.10 ÉVACUATION SUR L'ARRIÉRE ET AU DESSUS TERMINAISON VERTICALE ) < (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE 20 (6,1) REQUISE EN PIEDS (MÈTRES) V...
  • Page 104 ) > (V Configurations d'évacuation simples. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6) (6,1)
  • Page 105: Évacuation À L'arrière

    3.11 ÉVACUATION À L'ARRIÈRE AVERTISSEMENT IL EST ESSENTIEL QUE LE COUVERCLE D’ÉVACUATION SOIT INSTALLÉ, SI NON L’APPAREIL NE FONCTIONNERA PAS CORRECTEMENT ET POURRAIT CAUSER DES BLESSURES OU DES DOMMAGES MATÉRIELS. Enlevez l'écran de protection et vitre de la porte, référer de la section, « ENLÈVEMENT ET INSTALLATION DE LA PORTE ET L'ÉCRAN DE PROTECTION ».
  • Page 106: Déflecteur Du Ventilation Arrière (Pour L'application De Ventilation Arrière Seulement)

    3.12 DÉFLECTEUR DU VENTILATION ARRIÈRE (POUR L'APPLICATION DE VENTILATION ARRIÈRE SEULEMENT) Retirez l'assemblage de l'écran de protection et la porte de l'appareil, consultez la section « RETRAIT ET INSTALLATION DE L’ÉCRAN DE PROTECTION ET DE LA PORTE » du manuel pour obtenir des instructions détaillées.
  • Page 107: Évacuation Sur Le Dessus

    3.13 ÉVACUATION SUR LE DESSUS AVERTISSEMENT IL EST ESSENTIEL QUE LE COUVERCLE D’ÉVACUATION SOIT INSTALLÉ, SI NON L’APPAREIL NE FONCTIONNERA PAS CORRECTEMENT ET POURRAIT CAUSER DES BLESSURES OU DES DOMMAGES MATÉRIELS. REMARQUE: Cette appareil a été expédié avec une évacuation à l'arrière. OUTER COVERPLATE Enlevez l'écran de protection et vitre de la porte, référer de la section, «...
  • Page 108: Installation

    4.0 INSTALLATION AVERTISSEMENT AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE, ASSUREZ-VOUS DE RETIRER TOUTE COMPOSANTE NON FIXÉE À L’INTÉRIEUR DE LA CHAMBRE DE COMBUSTION. SI VOTRE APPAREIL COMPREND UN SYSTÈME DE TÉLÉCOMMANDE, ASSUREZ-VOUS QUE LE RÉCEPTEUR EST À LA POSITION « OFF » AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE.
  • Page 109: Installation Horizontale

    4.1.1 INSTALLATION HORIZONTALE AVERTISSEMENT L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. LA TERMINAISON NE DOIT PAS ÊTRE ENCHÂSSÉE DANS LE MUR OU LE REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. Cette confi guration s’applique lorsque le conduit d’évent traverse un mur extérieur.
  • Page 110: Utilisation De Composants Flexibles D'évacuation

    UTILISATION DE COMPOSANTS FLEXIBLES D’ÉVACUATION AVERTISSEMENT NE LAISSEZ PAS LA GAINE FLEXIBLE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES. GARDEZ-LA TENDUE. DES ESPACEURS SONT FIXÉS À LA GAINE FLEXIBLE À INTERVALLES PRÉDÉTERMINÉS AFIN DE GARDER UN ESPACE VIDE AVEC LE CONDUIT EXTÉRIEUR. POUR QUE LE FONCTIONNEMENT SOIT SÉCURITAIRE, UN CALFEUTRAGE ESPACE VIDE EST REQUIS.
  • Page 111: Installation De La Terminaison Verticale

    4.2.2 INSTALLATION DE LA TERMINAISON VERTICALE AVERTISSEMENT CONSERVEZ UN ESPACE MINIMAL DE 2" (51mm) ENTRE LA BASE DE LA PRISE D’AIR ET LE COLLET DE SOLIN. NOTE : Matériel de fi xation fourni avec les ensembles de terminal pour toit et raccord appropriées. Fixez le support de toit au toit à...
  • Page 112: Raccordement Des Évents À L'appareil

    4.2.3 RACCORDEMENT DES ÉVENTS À L'APPAREIL Raccordez la collet d’évacuation à l’appareil. Fixez avec un minimum de trois vis #8. Scellez le joint et les têtes de vis AUTOPER- avec le scellant à haute température Mill-Pac W573-0007 CEUSES (non fourni). #8 X 1/2”...
  • Page 113: Installation De La Terminaison Verticale

    4.3.2 INSTALLATION DE LA TERMINAISON VERTICALE Mettez l’appareil en place. CONDUIT Fixez le support de toit au toit à l’aide des vis fournies. Le support de INTÉRIEUR toit est optionnel. Dans ce cas, l’évent doit être supporté adéquatement, soit en utilisant une méthode alternative se conformant aux normes des autorités compétentes, soit en utilisant le support de toit optionnel.
  • Page 114: Renstreignant Des Évents Verticaux

    4.3.3 RENSTREIGNANT DES ÉVENTS VERTICAUX AVERTISSEMENT METTEZ HORS TENSION DE GAZ ET DE L'ALIMENTATION ÉLECTRIQUE AVANT D'INTERVENIR SUR L'APPAREIL. APPAREIL PEUT ÊTRE CHAUD, PAS DE SERVICE JUSQU'À CE QUE L'APPAREIL EST REFROIDI. AVERTISSEMENT POUR UNE UTILISATION SÛRE ET CORRECTE DE L'APPAREIL, SUIVEZ LES INSTRUCTIONS D'ÉVACUATION EXACTEMENT POUR ÉVITER LE RISQUE D'ASPHYXIE PAS LE SAC D'EMBALLAGE DE BÉBÉS ET LES ENFANTS.
  • Page 115: Terminaison Verticale À Travers Une Cheminée Existante

    TERMINAISON VERTICALE À TRAVERS UNE CHEMINÉE EXISTANTE AVERTISSEMENT RISQUE D'INCENDIE! LES CONFIGURATIONS D'ÉVACUATION COAXIALES À COLINÉAIRES NE DOIVENT ÊTRE UTILISÉES QUE DANS UNE CHEMINÉE OU UNE ENCEINTE DE NATURE INCOMBUSTIBLE. UNE INSTALLATION DANS UNE ENCEINTE COMBUSTIBLE PEUT CAUSER UN INCENDIE. Cet appareil est conçu pour être raccordé...
  • Page 116: Installation Dans Une Maison Mobile

    INSTALLATION DANS UNE MAISON MOBILE Cet appareil doit être effectuée en respectant les directives du fabricant et le Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, aux États-Unis, ou les normes actuelles pour les maisons mobiles, CAN/CSA Z240 SÉRIE MH, au Canada. Cet appareil ne doit être utilisé qu’avec le type de gaz indiqué sur la plaque d’homologation.
  • Page 117: Branchement Du Gaz

    BRANCHEMENT DU GAZ AVERTISSEMENT RISQUE D'INCENDIE, D'EXPLOSION OU D'ASPHYXIE. ASSUREZ-VOUS QU'IL N'Y AIT AUCUNE SOURCE D'ALLUMAGE COMME DES ÉTINCELLES OU UNE FLAMME NUE. SOUTENEZ LE CONTRÔLE DU GAZ LORSQUE VOUS ATTACHEZ LE TUYAU POUR ÉVITER DE PLIER LA CONDUITE DE GAZ. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 118: Ossature

    5.0 OSSATURE L'OSSATURE B36 AVERTISSEMENT RISQUE D’INCENDIE! AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CONTACT AVEC L’EXTÉRIEUR DU CAISSON, IL EST CONSEILLÉ D’INSTALLER L’APPAREIL CONTRE DES MURS FINIS (C.-À-D. PANNEAU DE GYPSE) COMME TOUT AUTRE MUR DE LA MAISON. CECI ASSURERA QUE LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES EST MAINTENU.
  • Page 119: Dimensions Minimales De L'ossature B36

    16" 40.6cm 5.1.1 DIMENSIONS MINIMALES DE L’OSSATURE B36 FRENCH 35" 88,9cm 16" 40,6cm W415-1678 / B / 03.27.17...
  • Page 120 Dégagements minimaux de l'appareil aux matériaux combustibles : Ossature combustible : 0" aux espaceurs 1" (25mm) en dessous et sur les côtés du conduit d’évent* 3" (76,2mm) au-dessus du conduit d’évent* Finition combustible : 0" à l’arrière 0" des côtés et du dessus en façade Évacuation sur le dessus 50 1/2"...
  • Page 121: Dégagements Minimaux De L'enceinte B36

    DÉGAGEMENTS MINIMAUX DE L'ENCEINTE B36 B36 ÉVACUATION SUR LE DESSUS ENCEINTE AVEC ÉVACUATION SUR LE DESSUS L'enceinte de l'appareil doit avoir une hauteur minimale de 50 1/2" (1,28m). Afin de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction.
  • Page 122 B36 DÉGAGEMENTS MINIMAUX DE ÉVACUATION À L'ARRIÈRE Pour la ventilation arrière ne dépassement pas 10" (254mm) de section horizontale de ventilation. NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. ENCEINTE AVEC ÉVACUATION À...
  • Page 123 B36 DÉGAGEMENTS MAXIMAUX DE ÉVACUATION À L'ARRIÈRE (EXEMPLE 1) NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (1,04m). Afin de respecter les contraintes de température, l’espace à...
  • Page 124 B36 DÉGAGEMENTS MAXIMAUX DE ÉVACUATION À L'ARRIÈRE (EXEMPLE 2) NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41" (1,04m). Afin de respecter les contraintes de température, l’espace à...
  • Page 125: L'ossature Gx36-1

    L'OSSATURE GX36-1 AVERTISSEMENT RISQUE D’INCENDIE! AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CONTACT AVEC L’EXTÉRIEUR DU CAISSON, IL EST CONSEILLÉ D’INSTALLER L’APPAREIL CONTRE DES MURS FINIS (C.-À-D. PANNEAU DE GYPSE) COMME TOUT AUTRE MUR DE LA MAISON. CECI ASSURERA QUE LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES EST MAINTENU.
  • Page 126: Dimensions Minimales De L'ossature Gx36-1

    5.3.1 DIMENSIONS MINIMALES DE L’OSSATURE GX36-1 16" 40.6cm FRENCH 35" 88,9cm 16" 40,6cm W415-1678 / B / 03.27.17...
  • Page 127 Dégagements minimaux de l'appareil aux matériaux combustibles: Ossature combustible : 0" aux espaceurs 1" (25mm) en dessous et sur les côtés du conduit d’évent* 3" (76,2mm) au-dessus du conduit d’évent* Finition combustible : 0" à l’arrière 0" des côtés et du dessus en façade Évacuation sur le dessus 50 1/2"...
  • Page 128: Dégagements Minimaux De L'enceinte Gx36-1

    DÉGAGEMENTS MINIMAUX DE L'ENCEINTE GX36-1 GX36-1 ÉVACUATION SUR LE DESSUS NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. * Voir la section « DIMENSIONS MINIMALE DE L'OSSATURE » pour plus d'informations sur la réduction d'évacuation tuyau supérieur dégagements.
  • Page 129 GX36-1 DÉGAGEMENTS MINIMAUX DE ÉVACUATION À L'ARRIÈRE Pour la ventilation arrière ne dépassement pas 10" (254mm) de section horizontale de ventilation. NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. ENCEINTE AVEC ÉVACUATION À...
  • Page 130 GX36-1 DÉGAGEMENTS MAXIMAUX DE ÉVACUATION À L'ARRIÈRE (EXEMPLE 1) NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 44" (1,11m). Afin de respecter les contraintes de température, l’espace à...
  • Page 131 GX36-1 DÉGAGEMENTS MAXIMAUX DE ÉVACUATION À L'ARRIÈRE (EXEMPLE 2) NOTE: L'écran protection est télescopique et doivent être ajusté à protection toute la profondeur de la pénétration de la paroi combustible. ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 44" (1,11m). Afin de respecter les contraintes de température, l’espace à...
  • Page 132: Matériau De Finition Incombustible

    MATÉRIAU DE FINITION INCOMBUSTIBLE AVERTISSEMENT: Les matériaux de finition incombustibles ne doivent pas dépasser de plus 4” (101,6mm) la façade de la porte (sur toutes côtés). Si des projections plus grandes sont requises, augmentez les dégagements des côtés et du dessus de 2" (50,1mm) pour chaque pouce (24,5mm) supplémentaire de projection.
  • Page 133: Installation Encadrée

    5.7 INSTALLATION ENCADRÉE WARNING L’INSTALLATION D’UNE TÉLÉVISION OU D’AUTRES APPAREILS ÉLECTRONIQUES DESSUS DE L’APPAREIL PEUT PROVOQUER LA DÉCOLORATION, FUSION OU DOMMAGE L’APPAREIL ÉLECTRONIQUE. UTILISER LES DÉGAGEMENTS À TITRE INDICATIF ET SE RÉFÉRER AUX INSTRUCTIONS DE VOTRE FABRICANT POUR PLUS D’INFORMATIONS. DÉGAGEMENTS MINIMUM 6"...
  • Page 134: Dégagements Minimaux De La Tablette

    DÉGAGEMENTS MINIMAUX DE LA TABLETTE AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ TOUS LES DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES SPÉCIFIÉS. NE PAS RESPECTER CES INSTRUCTIONS PEUT CAUSER UN INCENDIE OU UNE SURCHAUFFE. ASSUREZ-VOUS QUE TOUS LES DÉGAGEMENTS (ARRIÈRE, CÔTÉS, DESSUS, ÉVENTS, TABLETTE, FAÇADE, ETC.) SONT RESPECTÉS À LA LETTRE. LORSQUE VOUS UTILISEZ DE LA PEINTURE OU DU VERNIS COMME FINITION POUR VOTRE TABLETTE, ASSUREZ-VOUS QU’ILS SOIENT RÉSISTANTS À...
  • Page 135: Finitions

    6.0 FINITIONS AVERTISSEMENT RISQUE D’INCENDIE! N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE DEVANT DE L’APPAREIL. SI LA FINITION DE LA FAÇADE DE L’APPAREIL EST FAIT, ELLE DOIT ÊTRE FAITE DE MATÉRIAU INCOMBUSTIBLE COMME DE LA BRIQUE, DU MARBRE, DU GRANITE, ETC. NE FRAPPEZ PAS, NE CLAQUEZ PAS ET N’ÉGRATIGNEZ PAS LA PORTE VITRÉE. NE FAITES PAS FONCTIONNER L’APPAREIL LORSQUE LA PORTE VITRÉE EST ENLEVÉE, FISSURÉE, BRISÉE OU ÉGRATIGNÉE.
  • Page 136: L'avant Hotte D'installation

    Laissez une main sur la porte vitrée pendant l'enlèvement de la porte. La porte vitrée est maintenue en place par deux loquets située en haut et deux loquets en bas de la porte. Tirez les poignées des loquets vers l’avant, puis retirez les loquets du cadre de porte afin de libérer le haut de la porte.
  • Page 137: Disposition Des Bûches Du B36

    DISPOSITION DES BÛCHES DU B36 AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 138: Disposition Des Bûches Du Gx36-1

    DISPOSITION DES BÛCHES DU GX36-1 AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 139: Braises De Charbon

    BRAISES DE CHARBON AVERTISSEMENT LES BRAISES DE CHARBON DE BOIS, LA VERMICULITE ET LES MORCEAUX DE CHARBON NE DOIVENT PAS ÊTRE PLACÉS SUR LE BRÛLEUR. Éparpillez les braises à l’avant et sur les côtés du support à bûches de façon à créer un effet réaliste. N’utilisez pas la fi ne poussière qui reste au fond du sac.
  • Page 140: Schéma De Câblage

    7.0 SCHÉMA DE CÂBLAGE SCHÉMA DE CÂBLAGE ÉLECTRONIQUE DU B36 AVERTISSEMENT NE RACCORDEZ PAS L’INTERRUPTEUR MURAL OU LA SOUPAPE DE GAZ À L’ALIMENTATION ÉLECTRIQUE (110 VOLTS) Cette appareil est fourni avec une sauvegarde de pile. Si la sauvegarde est utilisé, installez 4 piles « AA » (non-fourni) dans la boîtier de piles et connectez au harnais de fi l.
  • Page 141: Schéma De Câblage Électronique Du Gx36-1

    SCHÉMA DE CÂBLAGE ÉLECTRONIQUE DU GX36-1 AVERTISSEMENT N’UTILISEZ PAS CE FOYER SI UNE PARTIE QUELCONQUE A ÉTÉ SUBMERGÉE. CONTACTEZ IMMÉDIATEMENT UN TECHNICIEN DE SERVICE QUALIFIÉ POUR INSPECTER L’APPAREIL POUR DES DOMMAGES AU CIRCUIT ÉLECTRIQUE. RISQUE DE CHOCS ÉLECTRIQUES OU D’EXPLOSION. NE BRANCHEZ PAS LE 110 V À LA SOUPAPE OU À...
  • Page 142 AVERTISSEMENT NE RACCORDEZ PAS L’INTERRUPTEUR MURAL OU LA SOUPAPE DE GAZ À L’ALIMENTATION ÉLECTRIQUE (110 VOLTS). FUSIBLE SOUFFLERIE DE COMBUSTION INTERFACE INTERFACE DIAGNOSTIQUE UTILISATEUR W415-1678 / B / 03.27.17...
  • Page 143: Fonctionnement (Électronique)

    8.0 FONCTIONNEMENT (ÉLECTRONIQUE) B36NTRE/GX36NTRE-1 & B36PTRE/GX36PTRE-1 AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 144: Fonctionnement (Millivolt)

    9.0 FONCTIONNEMENT (MILLIVOLT) B36NTR/GX36NTR-1 & B36PTR/GX36PTR-1 AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POUR- RAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 145: Réglages

    PILOT ELECTRODE BURNER 3/8” - 1/2” 10.0 RÉGLAGES (9.5mm - 12.7mm) 10.1 RÉGLAGE DE LA VEILLEUSE FLAME SENSOR Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz. VÉRIFIER LA PRESSION : FLAME MUST ENVELOP Pour vérifi er la pression d’arrivée, tournez la vis (A) vers la...
  • Page 146: Caractéristiques De La Flamme

    10.3 CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection 3/8” - 1/2” visuelle de la fl amme de la veilleuse et du brûleur. (9,5mm - 12,7mm) Comparez-les à ces illustrations. Si des fl ammes paraissent anormales, contactez un technicien de service. LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE...
  • Page 147: Entretien

    11.0 ENTRETIEN AVERTISSEMENT COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. L’APPAREIL PEUT ÊTRE CHAUD. ATTENDEZ QU’IL SOIT REFROIDI AVANT D’EN FAIRE L’ENTRETIEN. N’UTILISEZ PAS DE PRODUITS ABRASIFS. NE PEINTURE PAS L’ASSEMBLAGE DU VEILLEUSE. Assurez-vous que l’appareil fonctionne adéquatement une fois l’entretien terminé.
  • Page 148: Entretien Annuel

    11.1 ENTRETIEN ANNUEL AVERTISSEMENT LE CAISSON DEVIENT TRÈS CHAUD LORS DU FONCTIONNEMENT. LAISSEZ L’APPAREIL SE REFROIDIR COMPLÈTEMENT OU PORTEZ DES GANTS ANTICHALEUR AVANT D’EFFECTUER L’ENTRETIEN. AVERTISSEMENT NE JAMAIS ASPIRER DES BRAISES QUI SONT CHAUDES. NE PEINTUREZ PAS L’ASSEMBLAGE DE LA VEILLEUSE. •...
  • Page 149: Soins De La Vitre

    DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 11.3 SOINS DE LA VITRE NE PAS NETTOYER LA VITRE LORSQU’ELLE EST AVERTISSEMENT CHAUDE! N’EMPLOYEZ PAS DE DÉTERGENTS ABRASIFS POUR NETTOYER LA VITRE. Polissez légèrement à l’aide d’un linge propre et sec. LA VITRE CHAUDE CAUSERA Nettoyez les deux côtés de la vitre avec un nettoyeur DES BRÛLURES.
  • Page 150 W415-1678 / B / 03.27.17...
  • Page 151 W415-1678 / B / 03.27.17...
  • Page 152 W415-1678 / B / 03.27.17...
  • Page 153 W415-1678 / B / 03.27.17...
  • Page 154 W415-1678 / B / 03.27.17...
  • Page 155 W415-1678 / B / 03.27.17...
  • Page 156: B36 Accessories

    W415-1678 / B / 03.27.17...
  • Page 157: Gx36-1 Accessories

    W415-1678 / B / 03.27.17...
  • Page 158: Gx36-1 Accessories (Page 2)

    W415-1678 / B / 03.27.17...
  • Page 159: Guide De Dépannage (Électronique)

    15.0 GUIDE DE DÉPANNAGE (ÉLECTRONIQUE) AVERTISSEMENT MAINTENANCE MAINTENANCE MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 160 SYMPTÔME PROBLÈME SOLUTIONS Continue de Court-circuit ou connexion Vérifi ez toutes les connexions. Vérifi ez si les connexions produire desserrée dans la tige de la de l’assemblage de la veilleuse sont serrées; vérifi ez des étincelles sonde. aussi si ces connexions ne causent pas de mise à la et la veilleuse terre au niveau du métal.
  • Page 161: Guide De Dépannage (Millivolt)

    16.0 GUIDE DE DÉPANNAGE (MILLIVOLT) MAINTENANCE AVERTISSEMENT MAINTENANCE MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 162 SYMPTÔME PROBLÉME SOLUTIONS La veilleuse ne Aucune étincelle au brûleur de Vérifi ez si la veilleuse peut être allumée avec une allumette. s’allume pas. la veilleuse. Vérifi ez si le fi l est raccordé au bouton-poussoir d’ignition. Vérifi ez si le bouton-poussoir d’ignition doit être resserré. VEILLEUSE Remplacez le fi l si son isolant est brisé...
  • Page 163: Garantie

    17.0 GARANTIE Les produits NAPOLÉON sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits NAPOLÉON sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi és qui sont fi ers de leur travail.
  • Page 164 Foyers encastrés • Grils au charbon de bois • Foyers au gaz • Cascades d’eau Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030...