Summary of Contents for Continental Fireplaces BCDV48N

  • Page 1 W415-0327 / B / 12.07.07 $10.00 W415-0327 / B / 12.07.07...
  • Page 2: Table Of Contents

    TABLE of CONTENTS Framing PG 2-5 INTRODUCTION Minimum Mantel and Enclosure Clearances Warranty Nailing Tab Installation General Instructions General Information 19-20 FINISHING Care of Glass & Plated Parts Log Placement Installation overview Charcoal Embers Vermiculite 6 - 13 VENTING Glowing Embers Venting Lengths Logo Placement Minimum Air Terminal Location Clearances...
  • Page 3 CONTINENTAL® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Q uality Assurance Certifi cate. CONTINENTAL® products are designed with superior components and materials, assemble d by trained craftsmen who take great pride in their work. The burne r and valve assembly are leak and test-fir ed at a qua lity test s tation.
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BCDV48 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
  • Page 5: Installation Overview

    FIGURE 1 INSTALLATION OVERVIEW FIGURE 2 W415-0327 / B / 12.07.07...
  • Page 6: Venting

    VENTING For safe and proper operation of the fi replace follow the venting instruction exactly. Deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or carboning. Provide a means for visually checking the vent connection to the fi replace after the fi...
  • Page 7: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 3 W415-0327 / B / 12.07.07...
  • Page 8: Typical Minimum And Maximum Vent Lengths

    TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS NOTE: When terminating vertically, the restrictor plate W500- 0205 must be installed. Refer to Restricting Vertical Vents. FIGURES 4 a-b SPECIAL VENT INSTALLATIONS PERISCOPE TERMINATION Use only GD401 periscope kit to locate the air termination above grade.
  • Page 9: Venting Application Flow Chart

    VENTING APPLICATION FLOW CHART VERTICAL HORIZONTAL TERMINATION TERMINATION vertical rise vertical rise vertical rise vertical rise is equal to is less than is less than is equal to or greater horizontal horizontal or greater t h a n t h e t h a n t h e horizontal horizontal...
  • Page 10 DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calculations and feet inches examples are: 1° 0.03 15° 0.45 > - greater than 30° 11.0 > - equal to or greater than 45°* 1.35 16.0 < - less than 90°* 32.0 <...
  • Page 11 HORIZONTAL TERMINATION when (H ) > (V Example 2: Simple venting confi guration (only one 45º and 90° elbow) 90° FIGURE 9 90° See graph to determine the required FIGURE 8 vertical rise V for the required hori- 90° zontal run H 90°...
  • Page 12 VERTICAL TERMINATION when (H ) < (V Example 3: Simple venting confi gurations FIGURE 10 FIGURE 11 90° 90° 45° 45° 90° See graph to determine the required vertical rise V for the required horizontal run H = 5 ft = 10 ft = 5 + 10 = 15 ft = 3 ft...
  • Page 13 VERTICAL TERMINATION = 1 ft when (H ) > (V = 1.5 ft Simple venting confi gurations = 1 + 1.5 = 2.5 ft = 6 ft FIGURE 12 = 2 ft = 6 + 2 = 8 ft = .03 (one 45º elbow + three 90º elbow - 135º) = .03(45 + 90 + 90 + 90 - 135) = 5.4 ft = 8 + 5.4 = 13.4 ft = 13.4 + 2.5 = 15.9 ft...
  • Page 14: Installation

    INSTALLATION WALL AND CEILING PROTECTION HORIZONTAL VENT SECTIONS: A minimum clearance of 2" all FIGURE 17c around the vent pipe in all horizontal runs to combustibles is required. Use fi restop spacer W010-1778 (supplied). VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required.
  • Page 15: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS 2. Stretch the 5" fl exible vent pipe to FIGURE 22 Do not allow the inside fl exible FIGURE 20 the required length. Slip the vent pipe a vent pipe to bunch up on minimum of 2" over the inner sleeve of ELBOW horizontal or vertical runs and the air terminal connector and secure...
  • Page 16: Using Rigid Vent Components

    USING RIGID VENT COMPONENTS The vent system must be supported approximately every 3 feet for 4. Apply high temperature sealant W573- both vertical and horizontal runs. Use Wolf Steel vent spacers or 0002 (not supplied) to the outer edge of the equivalent every 3 feet and either side of each elbow to maintain of the outside sleeve of the air terminal.
  • Page 17: Gas Installation

    Conversion Kits GAS INSTALLATION The mobile home appliance is fi eld convertible between Natural Gas Proceed once the vent installation is complete. (NG) and Propane (LP). To convert from one gas to another consult your Continental dealer/ distributor. NOTE: All gas connections must be contained within the fi replace when complete.
  • Page 18: Minimum Mantel And Enclosure Clearances

    FIGURE 36 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Minimum clearance to combustible construction from fi replace and vent surfaces: Framing 0" to stand-offs Finishing 0" to rear, sides and bottom Non-combustible fi nishing 8" to top All around the vent pipe 2"...
  • Page 19: Nailing Tab Installation

    FINISHING NAILING TAB INSTALLATION 1) Attach the nailing tabs to the corner posts using the 2 LOG PLACEMENT / GLOWING EMBERS sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing PHAZER logs and glowing embers, exclusive to Continental® Fire- FIGURE 39 tab and then through the existing holes in the places, provide a unique and realistic glowing effect that is different...
  • Page 20: Charcoal Embers

    4. Place the small branch of log#5 into the notch on log#3. The notch GLOWING EMBERS on the charred edge of log#5 sits on the outer left grate post. Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 &...
  • Page 21: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION INSTALLATION TO BE threaded stud using the lock washer and wing nut provided. Ensure DONE BY A QUALIFIED that the blower does not touch the fi replace base or the fi rebox. INSTALLER and must be electrically connected Attach the connectors from the black and grounded in accord- and white wires to the thermodisc and...
  • Page 22: Operation / Maintenance

    OPERATION / MAINTENANCE After extended periods of non-operation such as following a vacation OPERATING INSTRUCTIONS or a warm weather season, the fi replace may emit a slight odour for When lit for the fi rst time, the fi replace will emit a slight odour for a a few hours.
  • Page 23: Adjustments

    ADJUSTMENTS Closing the air shutter will cause a more yellow fl ame, but can lead PILOT BURNER ADJUSTMENT to carboning. Opening the air shutter will cause a more blue fl ame, Adjust the pilot screw to provide properly sized fl ame. Turn in a but can cause fl...
  • Page 24: Replacements

    REPLACEMENTS Contact your dealer or the factory for questions concerning prices 1. M & S ODEL ERIAL UMBER OF FIREPLACE and policies on replacement parts. Normally all parts can be ordered 2. I NSTALLATION DATE OF FIREPLACE through your Continental® dealer or distributor. 3.
  • Page 25 W415-0327 / B / 12.07.07...
  • Page 26: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; Pilot fl ame is not large enough or - turn up pilot fl...
  • Page 27 SYMPTOM PROBLEM TEST SOLUTION Flames are consist- Unit is over-fi red or under-fi red. - check pressure readings: ently too large or too Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 small. Carboning oc- turns and then placing pressure gauge tubing over the test point. Gauge should curs.
  • Page 28 NOTES W415-0327 / B / 12.07.07...